![8.3 M&C via SNMP](/images/new-backgrounds/27533/27533157x1.webp)
8.3 M&C via SNMP
Set up the Mini Compact Outdoor SSPA with custom IP parameters by modifying the internal IP settings using Paradise Datacom’s Universal M&C, version 4.4.3 or later. Use the default Read and Write Community settings, or check the boxes to modify them. See Figure
The Protocol setting in the Settings tab of the Universal M&C needs to be set to SNMP, as shown in Figure
SNMP
Figure | Figure |
After the desired IP address, Subnet mask and Gateway parameters have been set, the unit will still use its default parameters. To make the new parameters active, reset the Mini Compact Outdoor SSPA by removing its AC power. Unplug the Quick Start cable from the M&C connector. (If the unit is restarted with the Quick Start cable connected, it will always come up with default IP settings). Apply power to the SSPA.
If the custom IP settings will be used in normal operation, the user must construct an IP cable or modify the Quick Start cable by disconnecting the interface control pins (pins j and e, Baud Select 0 and Baud Select 1) from ground. In this configuration, the SSPA will always use the saved communication control settings rather then rolling back to the default configuration.
Operations Manual, HPA3, Mini Compact Outdoor SSPA | 208143 REV - | 79 |