Paradise RA 5785 7 System Settings Data Values, # Bytes, Description, Limits and Byte Values

Models: RA 5785

1 82
Download 82 pages 33.99 Kb
Page 67
Image 67
Table 8-7: System Settings Data Values

Table 8-7: System Settings Data Values

Data

# Bytes

Description

Limits and Byte Values

Address

 

 

 

1

1

System Operation Mode

Single Amplifier = 255

1:1 Redundant = 0

 

 

 

2

1

System Hierarchical Address

Unit 1= 0; Unit 2= 255

3

1

Unit Start Up State

On Line Amplifier = 255

(in Redundancy)

Standby Amplifier = 0

 

 

4

1

Mute State

Mute Clear (Transmit Enable) = 255

Mute Set (Transmit Disable) = 0

 

 

 

5

1

Attenuation Level

[1 bit for every 0.1 dB]

0 dB attenuation = 0

(dB down from maximum gain)

 

 

20 dB attenuation = 200

 

 

 

6

1

RESERVE

N/A

7

1

Amplifier Network Address

1 to 255

8

1

High Temperature Alarm Threshold

0 to 100 (in oC)

 

 

 

Temperature Compensated = 255 (normal state)

9

1

SSPA module Calibration Mode

Tune Mode = 1 (Factory Use Only)

 

 

 

Calibration Mode = 0 (Factory Use Only)

10

1

SSPA Spare Fault Status

Ignore Spare Fault = 255

Fault on value of window on ADC channel = 0 to 1

 

 

 

Fault on External Mute = 8

 

 

 

Minor Fault (no effect on Summary Fault) = 255

11

1

SSPA Spare Fault Handling

Major Fault (Triggers Summary Fault) = 0

 

 

 

Major Fault with Mute (Transmit Disabled) = 1

12

1

Auxiliary Fault Status

Disabled = 255

Fault High = 0

 

 

 

Fault Low = 1

 

 

 

Minor Fault (no effect on Summary Fault) = 255

13

1

Auxiliary Fault Handling

Major Fault (Triggers Summary Fault) = 0

 

 

 

Major Fault with Mute (Transmit Disabled) = 1

14

1

BUC Fault Status

Enabled = 0

Disabled = 255

 

 

 

 

 

 

Minor Fault (no effect on Summary Fault) = 255

15

1

BUC Fault Handling

Major Fault (Triggers Summary Fault) =0

 

 

 

Major Fault with Mute (Transmit Disabled) = 1

16

1

Protocol Select

Serial = 255

IPNET (Ethernet UDP, Web M&C) = 3

 

 

 

SNMP = 4

 

 

 

9600 = 255

 

 

 

38400 = 0

17

1

Baud Rate Select

19200 = 1

 

 

 

4800 = 2

 

 

 

2400 = 3

18

1

Fiber Optic Fault Status

Disabled = 255

Fault on Logic High = 0

 

 

 

Fault on Logic Low = 1

 

 

 

Minor Fault (no effect on Summary Fault) = 255

19

1

Fiber Optic Fault Handling

Major Fault (Triggers Summary Fault) =0

 

 

 

Major Fault with Mute (Transmit Disabled) = 1

20

1

Standby Mode

Hot standby=255; Cold standby=0

21

1

BUC Reference

Autoswitch = 0; External = 1; Internal = 2

 

 

 

Disabled = 255

22

1

Forward RF Fault Status

Low RF Fault Threshold = 0

RF Window @ 10% = 1

 

 

 

RF Window @ 15% = 2

 

 

 

High RF Threshold = 3

 

 

(continued)

 

Note: Data length must be at least two bytes to form integer with the lower byte sent first. If an odd number of bytes is received, the last byte will be saved as the lower byte of the integer and the upper part will be zero.

Operations Manual, HPA3, Mini Compact Outdoor SSPA

208143 REV -

67

Page 67
Image 67
Paradise RA 5785 manual 7 System Settings Data Values, # Bytes, Description, Limits and Byte Values, Address