Table 8-7: System Settings Data Values
Data | # Bytes | Description | Limits and Byte Values | |
Address | ||||
|
|
| ||
1 | 1 | System Operation Mode | Single Amplifier = 255 | |
1:1 Redundant = 0 | ||||
|
|
| ||
2 | 1 | System Hierarchical Address | Unit 1= 0; Unit 2= 255 | |
3 | 1 | Unit Start Up State | On Line Amplifier = 255 | |
(in Redundancy) | Standby Amplifier = 0 | |||
|
| |||
4 | 1 | Mute State | Mute Clear (Transmit Enable) = 255 | |
Mute Set (Transmit Disable) = 0 | ||||
|
|
| ||
5 | 1 | Attenuation Level | [1 bit for every 0.1 dB] | |
0 dB attenuation = 0 | ||||
(dB down from maximum gain) | ||||
|
| 20 dB attenuation = 200 | ||
|
|
| ||
6 | 1 | RESERVE | N/A | |
7 | 1 | Amplifier Network Address | 1 to 255 | |
8 | 1 | High Temperature Alarm Threshold | 0 to 100 (in oC) | |
|
|
| Temperature Compensated = 255 (normal state) | |
9 | 1 | SSPA module Calibration Mode | Tune Mode = 1 (Factory Use Only) | |
|
|
| Calibration Mode = 0 (Factory Use Only) | |
10 | 1 | SSPA Spare Fault Status | Ignore Spare Fault = 255 | |
Fault on value of window on ADC channel = 0 to 1 | ||||
|
|
| Fault on External Mute = 8 | |
|
|
| Minor Fault (no effect on Summary Fault) = 255 | |
11 | 1 | SSPA Spare Fault Handling | Major Fault (Triggers Summary Fault) = 0 | |
|
|
| Major Fault with Mute (Transmit Disabled) = 1 | |
12 | 1 | Auxiliary Fault Status | Disabled = 255 | |
Fault High = 0 | ||||
|
|
| Fault Low = 1 | |
|
|
| Minor Fault (no effect on Summary Fault) = 255 | |
13 | 1 | Auxiliary Fault Handling | Major Fault (Triggers Summary Fault) = 0 | |
|
|
| Major Fault with Mute (Transmit Disabled) = 1 | |
14 | 1 | BUC Fault Status | Enabled = 0 | |
Disabled = 255 | ||||
|
|
| ||
|
|
| Minor Fault (no effect on Summary Fault) = 255 | |
15 | 1 | BUC Fault Handling | Major Fault (Triggers Summary Fault) =0 | |
|
|
| Major Fault with Mute (Transmit Disabled) = 1 | |
16 | 1 | Protocol Select | Serial = 255 | |
IPNET (Ethernet UDP, Web M&C) = 3 | ||||
|
|
| SNMP = 4 | |
|
|
| 9600 = 255 | |
|
|
| 38400 = 0 | |
17 | 1 | Baud Rate Select | 19200 = 1 | |
|
|
| 4800 = 2 | |
|
|
| 2400 = 3 | |
18 | 1 | Fiber Optic Fault Status | Disabled = 255 | |
Fault on Logic High = 0 | ||||
|
|
| Fault on Logic Low = 1 | |
|
|
| Minor Fault (no effect on Summary Fault) = 255 | |
19 | 1 | Fiber Optic Fault Handling | Major Fault (Triggers Summary Fault) =0 | |
|
|
| Major Fault with Mute (Transmit Disabled) = 1 | |
20 | 1 | Standby Mode | Hot standby=255; Cold standby=0 | |
21 | 1 | BUC Reference | Autoswitch = 0; External = 1; Internal = 2 | |
|
|
| Disabled = 255 | |
22 | 1 | Forward RF Fault Status | Low RF Fault Threshold = 0 | |
RF Window @ 10% = 1 | ||||
|
|
| RF Window @ 15% = 2 | |
|
|
| High RF Threshold = 3 | |
|
| (continued) |
|
Note: Data length must be at least two bytes to form integer with the lower byte sent first. If an odd number of bytes is received, the last byte will be saved as the lower byte of the integer and the upper part will be zero.
Operations Manual, HPA3, Mini Compact Outdoor SSPA | 208143 REV - | 67 |