3.3.2 Universal M&C Settings Window

3.3.2 Universal M&C Settings Window

Figure 3-10shows the ‘Settings’ window of the Paradise Datacom Universal M&C Software. The ‘Settings’ window contains many of the global settings that are available in the SSPA.

1

2

3

4

IPNET

 

5

 

 

 

 

 

 

 

 

6

 

 

 

7

8

12

 

 

13

9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

 

 

 

 

 

 

 

11

Figure 3-10: Universal M&C, Settings

Power Up Settings

The Mini Compact Outdoor amplifier will power up with the “last-state” settings before the unit was powered down. Whatever attenuation setting or mute state the amplifier was in when powered down will be the restored settings when the amplifier is powered back on.

[1] Operation Mode: Select between stand alone (single unit) or redundancy mode of operation.

[2] Hierarchical Address: Identifies each amplifier in a redundant system as HPA 1 or HPA 2.

[3] Redundant Startup State: Selects whether the unit should start up as the on-line amplifier or the standby amplifier.

[4] Mute State: Determines if the unit should start up muted (transmit disabled) or mute clear (transmit enabled).

[5] Protocol Select: Selects between Serial, IPNET or SNMP protocols. You will be asked to verify that you wish to change the Protocol. Communication with the amplifier may be affected.

[6] Baud Rate Select: Sets the baud rate of the unit. The supported baud rates

include: 2400, 4800, 9600, 19200, and 38400 baud. The factory default baud