2.2.4.2 Serial I/O Control (J4)
For serial data control of the Compact Outdoor SSPA, a
Both
The Mini Compact Outdoor Amplifier may be supplied with a Quick Start Cable in which this connection is already made. This allows the user to quickly setup the amplifier and verify its operation. The other side of the cable has a
Communication links using
2.2.5 Link Port (J5) [MS3112E10-6S]
The interface connector is used to connect between two Compact Outdoor Amplifiers when used in a 1:1 redundant system. It is a
Table 2-3: J5 Link Port Pin-Outs
Pin # | Connection | Pin # | Connection |
A | Link Out | D | N/C |
|
|
|
|
B | Link In | E | N/C |
C | N/C | F | Ground |
|
|
|
|
2.2.6 Switch Port (J6) [MS3112E10-6S]
When used in a 1:1 redundant system, the waveguide switch must be connected to the switch port of each amplifier
Table 2-4: J6 Switch Port Pin-Outs
Pin # | Connection | Pin # | Connection |
A | N/C | D | N/C |
|
|
|
|
B | N/C | E | Pos 2 |
C | +28 VDC | F | Pos 1 |
|
|
|
|
Operations Manual, HPA3, Mini Compact Outdoor SSPA | 208143 REV - | 17 |