76
208143 REV - Operations Manual, HPA3, Mini Compact Outdoor SSPA
settingIndex/settingValue | settingTextValue | Value OID | Description | |
|
|
|
| |
1/INTEGER | SystemMode'1:1=0,Dual 1:1 = 1,MSwitch=2,StandAlone=255 | 1.3.6.1.4.1.20712.2.1.1.1.2.1 | System Operation mode | |
|
|
|
| |
2/INTEGER | SystemHierarchicalAddress'HPA1=0,HPA2=255 | 1.3.6.1.4.1.20712.2.1.1.1.2.2 | System Hierarchical Address | |
|
|
|
| |
3/INTEGER | CurrentState'UnitStandby=0,UnitOnline=255 | 1.3.6.1.4.1.20712.2.1.1.1.2.3 | Unit Start Up State in Redundancy | |
|
|
|
| |
4/INTEGER | Mute'On=0,Off=255 | 1.3.6.1.4.1.20712.2.1.1.1.2.4 | Mute State | |
|
|
|
| |
5/INTEGER | SSPAAttenuation(dBx10)'0..200 | 1.3.6.1.4.1.20712.2.1.1.1.2.5 | Attenuation Level | |
|
|
|
| |
6/INTEGER | Reserved'0..255 | 1.3.6.1.4.1.20712.2.1.1.1.2.6 | Field reserved for future use | |
|
|
|
| |
7/INTEGER | NetworkAddress'0..255 | 1.3.6.1.4.1.20712.2.1.1.1.2.7 | Amplifier Network Address | |
|
|
|
| |
8/INTEGER | HighTempAlarmThreshold(C)'0..100 | 1.3.6.1.4.1.20712.2.1.1.1.2.8 | High Temperature Alarm Threshold | |
|
|
|
| |
9/INTEGER | CalibrationMode'On=0,Off=255 | 1.3.6.1.4.1.20712.2.1.1.1.2.9 | SSPA module Calibration Mode | |
|
|
|
| |
10/INTEGER | 1.3.6.1.4.1.20712.2.1.1.1.2.10 | SSPA Spare Fault Status | ||
|
|
|
| |
11/INTEGER | SpareFaultAction'MajorFault=0,Fault+Mute=1,MinorFault=255 | 1.3.6.1.4.1.20712.2.1.1.1.2.11 | SSPA Spare Fault Handling | |
|
|
|
| |
12/INTEGER | AuxFaultCheck'LogicHigh=0,LogicLow=1,Ignore=255 | 1.3.6.1.4.1.20712.2.1.1.1.2.12 | SSPA Auxiliary Fault Status | |
|
|
|
| |
13/INTEGER | AuxFaultAction'MajorFault=0,Fault+Mute=1,MinorFault=255 | 1.3.6.1.4.1.20712.2.1.1.1.2.13 | SSPA Auxiliary Fault Handling | |
|
|
|
| |
14/INTEGER | BUCFaultCheck'Enable=0,Disable=255 | 1.3.6.1.4.1.20712.2.1.1.1.2.14 | Block Up Converter Fault Status | |
|
|
|
| |
15/INTEGER | BUCFaultAction'MajorFault=0,Fault+Mute=1,MinorFault=255 | 1.3.6.1.4.1.20712.2.1.1.1.2.15 | Block Up Converter Fault Handling | |
|
|
|
| |
16/INTEGER | ProtocolSelect'IPNET=3,SNMP=4,Serial=255 | 1.3.6.1.4.1.20712.2.1.1.1.2.16 | Protocol Select | |
|
|
|
| |
17/INTEGER | BaudRate'38400=255,19200=1,4800=2,2400=3,9600=255 | 1.3.6.1.4.1.20712.2.1.1.1.2.17 | Baud Rate Select | |
|
|
|
| |
18/INTEGER | FiberFaultCheck'LogicHigh=0,LogicLow=1,Ignore=255 | 1.3.6.1.4.1.20712.2.1.1.1.2.18 | Fiber Converter Fault Status | |
|
|
|
| |
19/INTEGER | Reserved'0..255 | 1.3.6.1.4.1.20712.2.1.1.1.2.19 | Fiber Converter Fault Handling | |
|
|
|
| |
20/INTEGER | StandbyMode'ColdStandby=0,HotStandby=255 | 1.3.6.1.4.1.20712.2.1.1.1.2.20 | Standby Mode | |
|
|
|
| |
21/INTEGER | BUCReference'Autoswitch=0,External=1,Internal=2,NA=255 | 1.3.6.1.4.1.20712.2.1.1.1.2.21 | BUC Reference | |
|
|
|
| |
22/INTEGER | FwdRFCheck'LowRF=0,Window10%=1,Window15%=2, | 1.3.6.1.4.1.20712.2.1.1.1.2.22 | Type of forward RF fault | |
HighRF=3,Dis=255 | ||||
|
|
| ||
|
|
|
| |
23/INTEGER | RFFaultAction'MajorFault=0,MinorFault=255 | 1.3.6.1.4.1.20712.2.1.1.1.2.23 | Forward RF fault handling | |
|
|
|
| |
24/INTEGER | FrwdRFFaultThreshold(dBm)'0..80 | 1.3.6.1.4.1.20712.2.1.1.1.2.24 | Forward RF Fault threshold level in dBm | |
|
|
|
| |
25/INTEGER | Reserved'0..255 | 1.3.6.1.4.1.20712.2.1.1.1.2.25 | Field reserved for future use | |
|
|
|
| |
26/INTEGER | Reserved'0..255 | 1.3.6.1.4.1.20712.2.1.1.1.2.26 | Field reserved for future use | |
|
|
|
| |
27/INTEGER | Reserved'0..255 | 1.3.6.1.4.1.20712.2.1.1.1.2.27 | Field reserved for future use | |
|
|
|
| |
28/INTEGER | Reserved'0..255 | 1.3.6.1.4.1.20712.2.1.1.1.2.28 | Field reserved for future use | |
|
|
|
|
Table