Paradise RA 5785 manual settingIndex/settingValue, settingTextValue, Value OID, Description

Models: RA 5785

1 82
Download 82 pages 33.99 Kb
Page 76
Image 76
settingIndex/settingValue

76

208143 REV - Operations Manual, HPA3, Mini Compact Outdoor SSPA

settingIndex/settingValue

settingTextValue

Value OID

Description

 

 

 

 

1/INTEGER

SystemMode'1:1=0,Dual 1:1 = 1,MSwitch=2,StandAlone=255

1.3.6.1.4.1.20712.2.1.1.1.2.1

System Operation mode

 

 

 

 

2/INTEGER

SystemHierarchicalAddress'HPA1=0,HPA2=255

1.3.6.1.4.1.20712.2.1.1.1.2.2

System Hierarchical Address

 

 

 

 

3/INTEGER

CurrentState'UnitStandby=0,UnitOnline=255

1.3.6.1.4.1.20712.2.1.1.1.2.3

Unit Start Up State in Redundancy

 

 

 

 

4/INTEGER

Mute'On=0,Off=255

1.3.6.1.4.1.20712.2.1.1.1.2.4

Mute State

 

 

 

 

5/INTEGER

SSPAAttenuation(dBx10)'0..200

1.3.6.1.4.1.20712.2.1.1.1.2.5

Attenuation Level

 

 

 

 

6/INTEGER

Reserved'0..255

1.3.6.1.4.1.20712.2.1.1.1.2.6

Field reserved for future use

 

 

 

 

7/INTEGER

NetworkAddress'0..255

1.3.6.1.4.1.20712.2.1.1.1.2.7

Amplifier Network Address

 

 

 

 

8/INTEGER

HighTempAlarmThreshold(C)'0..100

1.3.6.1.4.1.20712.2.1.1.1.2.8

High Temperature Alarm Threshold

 

 

 

 

9/INTEGER

CalibrationMode'On=0,Off=255

1.3.6.1.4.1.20712.2.1.1.1.2.9

SSPA module Calibration Mode

 

 

 

 

10/INTEGER

SpareFaultCheck'ADCCh0-1=0..1,Ext.Mute=8,Ignore=255

1.3.6.1.4.1.20712.2.1.1.1.2.10

SSPA Spare Fault Status

 

 

 

 

11/INTEGER

SpareFaultAction'MajorFault=0,Fault+Mute=1,MinorFault=255

1.3.6.1.4.1.20712.2.1.1.1.2.11

SSPA Spare Fault Handling

 

 

 

 

12/INTEGER

AuxFaultCheck'LogicHigh=0,LogicLow=1,Ignore=255

1.3.6.1.4.1.20712.2.1.1.1.2.12

SSPA Auxiliary Fault Status

 

 

 

 

13/INTEGER

AuxFaultAction'MajorFault=0,Fault+Mute=1,MinorFault=255

1.3.6.1.4.1.20712.2.1.1.1.2.13

SSPA Auxiliary Fault Handling

 

 

 

 

14/INTEGER

BUCFaultCheck'Enable=0,Disable=255

1.3.6.1.4.1.20712.2.1.1.1.2.14

Block Up Converter Fault Status

 

 

 

 

15/INTEGER

BUCFaultAction'MajorFault=0,Fault+Mute=1,MinorFault=255

1.3.6.1.4.1.20712.2.1.1.1.2.15

Block Up Converter Fault Handling

 

 

 

 

16/INTEGER

ProtocolSelect'IPNET=3,SNMP=4,Serial=255

1.3.6.1.4.1.20712.2.1.1.1.2.16

Protocol Select

 

 

 

 

17/INTEGER

BaudRate'38400=255,19200=1,4800=2,2400=3,9600=255

1.3.6.1.4.1.20712.2.1.1.1.2.17

Baud Rate Select

 

 

 

 

18/INTEGER

FiberFaultCheck'LogicHigh=0,LogicLow=1,Ignore=255

1.3.6.1.4.1.20712.2.1.1.1.2.18

Fiber Converter Fault Status

 

 

 

 

19/INTEGER

Reserved'0..255

1.3.6.1.4.1.20712.2.1.1.1.2.19

Fiber Converter Fault Handling

 

 

 

 

20/INTEGER

StandbyMode'ColdStandby=0,HotStandby=255

1.3.6.1.4.1.20712.2.1.1.1.2.20

Standby Mode

 

 

 

 

21/INTEGER

BUCReference'Autoswitch=0,External=1,Internal=2,NA=255

1.3.6.1.4.1.20712.2.1.1.1.2.21

BUC Reference

 

 

 

 

22/INTEGER

FwdRFCheck'LowRF=0,Window10%=1,Window15%=2,

1.3.6.1.4.1.20712.2.1.1.1.2.22

Type of forward RF fault

HighRF=3,Dis=255

 

 

 

 

 

 

 

23/INTEGER

RFFaultAction'MajorFault=0,MinorFault=255

1.3.6.1.4.1.20712.2.1.1.1.2.23

Forward RF fault handling

 

 

 

 

24/INTEGER

FrwdRFFaultThreshold(dBm)'0..80

1.3.6.1.4.1.20712.2.1.1.1.2.24

Forward RF Fault threshold level in dBm

 

 

 

 

25/INTEGER

Reserved'0..255

1.3.6.1.4.1.20712.2.1.1.1.2.25

Field reserved for future use

 

 

 

 

26/INTEGER

Reserved'0..255

1.3.6.1.4.1.20712.2.1.1.1.2.26

Field reserved for future use

 

 

 

 

27/INTEGER

Reserved'0..255

1.3.6.1.4.1.20712.2.1.1.1.2.27

Field reserved for future use

 

 

 

 

28/INTEGER

Reserved'0..255

1.3.6.1.4.1.20712.2.1.1.1.2.28

Field reserved for future use

 

 

 

 

Table 8-11: Detailed Settings for Mini CO SSPA mode (Device Type=8)