Genie S-80 Function Tests, At the Ground Controls, 3Always perform function tests prior to use

Models: 43650 S-85 S-80

1 33
Download 33 pages 2.95 Kb
Page 18
Image 18
Function Tests

Operator's Manual

Second Edition· Fifth Printing

 

 

 

 

Function Tests

Do Not Operate Unless:

You learn and practice the principles of safe machine operation contained in this operator's manual.

1Avoid hazardous situations.

2Always perform a pre-operation inspection.

3Always perform function tests prior to use.

Know and understand the above principles before going on to the next section.

4Inspect the work place.

5Only use the machine as it was intended.

Fundamentals

The Function Tests are designed to discover any malfunctions before the machine is put into service. The operator must follow the step-by-step instructions to test all machine functions.

A malfunctioning machine must never be used. If malfunctions are discovered, the machine must be tagged and removed from service. Repairs to the machine may only be made by a qualified service technician, according to the manufacturer's specifications.

After repairs are completed, the operator must perform a pre-operation inspection and function tests again before putting the machine into service.

1Select a test area that is firm, level and free of obstruction.

At the Ground Controls

2Turn the key switch to ground control.

3Pull out the red Emergency Stop button to the ON position.

Result: Beacon (if equipped) should flash.

4Start the engine (see Starting The Engine, page 17).

Test Emergency Stop

5Push in the red Emergency Stop button to the OFF position.

Result: Engine should turn off and all functions should not operate.

6Pull out the red Emergency Stop button to the ON position and restart the engine.

Test the Extendable Axles

7Hold the function enable switch to either side and activate the boom raise function.

Result: The boom should raise to horizontal and then stop. The boom should not raise above the limit switch unless both axles are extended.

8Hold the function enable switch to either side and activate the boom lower function.

Result: The boom should lower and return to the stowed position.

16

Genie S-80 & Genie S-85

Part No. 43650

Page 18
Image 18
Genie S-80, S-85 Function Tests, At the Ground Controls, 3Always perform function tests prior to use, Test Emergency Stop