Genie S-85, S-80, 43650 manual Electrocution Hazards, Tip-overHazards

Models: 43650 S-85 S-80

1 33
Download 33 pages 2.95 Kb
Page 4
Image 4
Electrocution Hazards

Operator's Manual

Second Edition· Fifth Printing

 

 

 

 

SAFETY RULES

Electrocution Hazards

This machine is not electrically insulated and will not provide protection from contact with or proximity to electrical current.

Maintain safe distances from electrical power lines and apparatus in accordance with applicable governmental regulations and the following chart.

Voltage

Minimum Safe

Phase to Phase

Approach Distance

 

Feet

Meters

 

 

0 to 300V

Avoid Contact

 

 

 

300V to 50KV

10

3.05

 

 

 

50KV to 200KV

15

4.60

 

 

 

200KV to 350KV

20

6.10

 

 

 

350KV to 500KV

25

7.62

 

 

 

500KV to 750KV

35

10.67

 

 

 

750KV to 1000KV

45

13.72

 

 

 

Allow for platform movement, electrical line sway or sag and beware of strong or gusty winds.

Keep away from the machine if it contacts energized power lines. Personnel on the ground or in the platform must not touch or operate the machine until energized power lines are shut off.

Do not operate the machine during lightning or storms.

Do not use the machine as a ground for welding.

Tip-over Hazards

Occupants and equipment shall not exceed the maximum platform capacity.

Maximum platform capacity

 

 

S-85

500 lbs

227 kg

 

 

 

Maximum platform capacity

 

 

S-80 with 8 Ft Platform

500 lbs

227 kg

 

 

 

Maximum platform capacity

 

 

S-80 with 6 Ft Platform

600 lbs

272 kg

 

 

 

Maximum platform capacity

 

 

S-80 with 6 Ft Platform

 

 

with foam-filled tires and proper

 

 

counterweight configuration

750 lbs

340 kg

 

 

 

Maximum occupants

 

2

 

 

 

2

Genie S-80 & Genie S-85

Part No.43650

Page 4
Image 4
Genie S-85, S-80, 43650 manual Electrocution Hazards, Tip-overHazards