Genie S-85 Engine Idle Select rpm, Check Engine Light if equipped, Stopping the Engine, Generator

Models: 43650 S-85 S-80

1 33
Download 33 pages 2.95 Kb
Page 28
Image 28
Generator

Operator's Manual

Second Edition· Fifth Printing

 

 

 

 

OPERATING INSTRUCTIONS

Generator

To operate generator, move the generator toggle switch to the generator position. The engine will continue to run but no drive or platform functions will operate.

Plug power tool into the power to platform GFCI outlet.

To resume machine functions, move generator toggle switch to machine functions position. All functions will operate.

Engine Idle Select (rpm)

Select engine idle (rpm) using the symbols on the control panel.

·Rabbit and foot switch symbol: foot switch activated high idle

·Turtle symbol: low idle

·Rabbit symbol: high idle

Check Engine Light (if equipped)

Light on and engine stopped: Tag the machine and remove from service.

Light on and engine still running: Contact service personnel within 24 hours.

Stopping the Engine

Push in the red Emergency Stop button and turn the key switch to the OFF position.

After Each Use

1Select a safe parking location—firm level surface, clear of obstruction and traffic.

2Retract and lower the boom to the stowed position.

3Rotate the turntable so that the boom is between the non-steering wheels.

4Turn the key switch to the OFF position and remove the key to secure from unauthorized use.

5Chock the wheels.