6 SET MODE

SET mode programming

SET mode is used to change the conditions of 11 transceiver functions: beep tone, scan type, scan resure timer, auto scan, monitor action, automatic backlighting, LCD contrast, auto power save, self check, battery voltage and S/RF meter.

qTurn power OFF.

wWhile pushing [SQL•MONI], turn power ON and continue pushing [SQL•MONI] until “bP” appears.

eRelease [SQL•MONI].

rPush [Y]/[Z] to select the desired condition of the item. t Push [SQL•MONI] to select the desired item, if necessary. y To exit SET mode, turn the power OFF, then ON again, or

push [16•C].

SET MODE CONSTRUCTION

Battery

S/RF

Beep tone

Scan

Scan resume

voltage

meter

type

timer

 

 

 

 

Starting item

 

Self

 

 

 

 

Auto

check

 

 

MONI

 

scan

 

 

 

 

 

 

 

Push

SQL

 

 

Auto

 

LCD

 

Automatic

Monitor

power save

contrast

backlighting

action

SET mode items

DBeep tone “bP”

You can select silent operation by turning beep tones OFF or you can have confirmation beeps sound at the push of a switch by turning beep tones ON.

AUTO (At): Beep tone is linked with volume tone.

1–10: Beep tone scale is set from 1–10 scale (Max. is 10).

Beep tone AUTO (default)

DPriority scan function “Pr”

The transceiver has 2 scan types. Normal scan and priority scan. Normal scan searches all tag channels in the selected channel group. Priority scan searches all tag channels in se- quence while monitoring Channel 16.

Priority scan (default)