6 SET MODE

■SET mode programming

SET mode is used to change the conditions of 11 transceiver functions: beep tone, scan type, scan resure timer, auto scan, monitor action, automatic backlighting, LCD contrast, auto power save, self check, battery voltage and S/RF meter.

qTurn power OFF.

wWhile pushing [SQL•MONI], turn power ON and continue pushing [SQL•MONI] until “bP” appears.

eRelease [SQL•MONI].

rPush [Y]/[Z] to select the desired condition of the item. t Push [SQL•MONI] to select the desired item, if necessary. y To exit SET mode, turn the power OFF, then ON again, or

push [16•C].

SET MODE CONSTRUCTION

Battery

S/RF

Beep tone

Scan

Scan resume

voltage

meter

type

timer

 

 

 

 

Starting item

 

Self

 

 

 

 

Auto

check

 

 

MONI

 

scan

 

 

 

 

 

 

 

Push

SQL

 

 

Auto

 

LCD

 

Automatic

Monitor

power save

contrast

backlighting

action

■SET mode items

DBeep tone “bP”

You can select silent operation by turning beep tones OFF or you can have confirmation beeps sound at the push of a switch by turning beep tones ON.

•AUTO (At): Beep tone is linked with volume tone.

•1–10: Beep tone scale is set from 1–10 scale (Max. is 10).

Beep tone AUTO (default)

DPriority scan function “Pr”

The transceiver has 2 scan types. Normal scan and priority scan. Normal scan searches all tag channels in the selected channel group. Priority scan searches all tag channels in se- quence while monitoring Channel 16.

Priority scan (default)

13

Page 18
Image 18
Genius IC-M21 instruction manual SET Mode, SET mode programming, SET mode items, Beep tone bP, Priority scan function Pr