Electrical Connection Legal Requirements

Connection to the electricity supply should be made via a properly earthed, readily accessible wall socket which is adjacent to and not more than 1.25m away from the appliance. The socket must be capable of electrical isolation. The mains lead should be routed such that it cannot touch hot parts of the cooker i.e. the back panel above a height of 650mm from the floor.

Should this plug not fit the socket outlet in your home it should be cut off and replaced with a suitable plug as outlined below.

IMPORTANT NOTE: The severed plug cannot be used for any other appliance and should therefore be properly disposed of in a safe manner. DO NOT LEAVE where children might find it and plug into a supply socket - This is an obvious hazard and extremely dangerous.

We recommend that the appliance is connected by a competent electrical installer, who is a member of a recognised "competent persons" scheme and who will comply with the I.E.E. and local regulations.

Where a fixed connections is used, a device allowing the appliance to be isolated on all poles from the mains supply with a contact opening width of at least 3mm must be provided.

If the Fitted Plug is Removed

This appliance must be earthed.

Important: Ensure that you route all mains electrical cables well clear of any adjacent heat source, such as an oven or grill.

The flexible mains lead must be correctly connected as below to a three pin plug of not less than 13amp capacity. If a BS 1363 plug is used, then it must be fitted with a 3amp fuse approved to BS 1362.

IMPORTANT: The wires in the mains lead fitted to this appliance are coloured

in accordance with the following code:

Blue to

Neutral

GREEN AND YELLOW

- Earth

 

BLUE

- Neutral

Mains Lead Clamp

BROWN

- Live

 

Green &

Yellow to

Earth

Brown to

Live

13 Amp Fuse

As the colours of the wires in the mains lead of this appliance may not correspond with the coloured markings identifying the terminals in your plug, proceed as follows:- The wire which is coloured green and yellow must be connected to the terminal in the plug marked with the letter 'E' or by the earth symbol or coloured k green or green and yellow. When connection is completed, close the terminal block, ensuring the cover is engaged on the locking tabs.