Goodman Mfg GMV95/GCV9 GMV95 DIMENSIONS, Minimum Clearances To Combustible Materials, SS-GMV95

Models: GMV95/GCV9 Multi-Position, Two-Stage/Variable-Speed Gas Furnace

1 16
Download 16 pages 46.91 Kb
Page 4
Image 4
GMV95 DIMENSIONS

PRODUCT SPECIFICATIONS

GMV95 DIMENSIONS

Model

A

B

C

D

E

GMV950453BXB

17½”

16”

13⅛”

12⅛”

13⅝”

GMV950704CXB

21”

19½”

16⅛”

16

17½”

GMV950905DXB

24½”

23”

20⅝”

19⅜”

20⅞”

GMV951155DXB

24½”

23”

20⅝”

19⅜”

20⅞”

Notes:

Installer must supply one or two PVC pipes: one for combustion air (optional) and one for the flue outlet (required). Vent pipe must be either 2” or 3” in diameter, depending upon furnace input, number of elbows, length of run and installation

(1 or 2 pipes). The optional Combustion Air Pipe is dependent on installation/code requirements and must be 2” or 3” diameter PVC.

Line voltage wiring can enter through the right or left side of the furnace. Low-voltage wiring can enter through the right or left side of furnace.

Conversion kits for high-altitude natural gas operation are available. Contact your Goodman distributor or dealer for details.

Installer must supply following gas line fittings, according to which entrance is used: Left—Two 90º elbows, one close nipple, straight pipe

Right—Straight pipe to reach gas valve

For bottom return: Failure to unfold flanges may reduce airflow by up to 18%. This could result in performance and noise issues.

MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS

Position

Sides

Rear

Front

Bottom

Flue

Top

Upflow

0”

0”

3”

C

0”

1”

Horizontal

6”

0”

3”

C

0”

6”

C = If placed on combustible floor, the floor MUST be wood ONLY.

Notes:

For servicing or cleaning, a 24” front clearance is required.

Unit connections (electrical, flue and drain) may necessitate greater clearances than the minimum clearances listed above.

In all cases, accessibility clearance must take precedence over clearances from the enclosure where accessibility clear- ances are greater.

4

www.goodmanmfg.com

SS-GMV95

 

 

 

Page 4
Image 4