PRODUCT SPECIFICATIONS
GMV95 HIGH- OR SINGLE-STAGE COOLING SPEEDS
GMV950453BXB
Cooling | Adjust | CFM¹ | |
Speed Tap | Tap | ||
| |||
|
|
| |
A | Minus | 540 | |
Normal | 600 | ||
| Plus (+) | 660 | |
B | Minus | 720 | |
Normal | 800 | ||
| Plus (+) | 880 | |
C | Minus | 900 | |
Normal | 1,000 | ||
| Plus (+) | 1,100 | |
D | Minus | 1,080 | |
Normal | 1,200 | ||
| Plus (+) | 1,320 |
GMV950704CXB
Cooling | Adjust | CFM¹ | |
Speed Tap | Tap | ||
| |||
|
|
| |
A | Minus | 540 | |
Normal | 600 | ||
| Plus (+) | 660 | |
B | Minus | 720 | |
Normal | 800 | ||
| Plus (+) | 880 | |
C | Minus | 990 | |
Normal | 1,100 | ||
| Plus (+) | 1,210 | |
D | Minus | 1,286 | |
Normal | 1,429 | ||
| Plus (+) | 1,572 |
GMV950905DXB
Cooling | Adjust | CFM¹ | |
Speed Tap | Tap | ||
| |||
|
|
| |
A | Minus | 720 | |
Normal | 800 | ||
| Plus (+) | 880 | |
B | Minus | 990 | |
Normal | 1,100 | ||
| Plus (+) | 1,210 | |
C | Minus | 1,260 | |
Normal | 1,400 | ||
| Plus (+) | 1,540 | |
D | Minus | 1,620 | |
Normal | 1,800 | ||
| Plus (+) | 1,980 |
GMV951155DXB
Cooling | Adjust | CFM¹ | |
Speed Tap | Tap | ||
| |||
|
|
| |
A | Minus | 720 | |
Normal | 800 | ||
| Plus (+) | 880 | |
B | Minus | 990 | |
Normal | 1,100 | ||
| Plus (+) | 1,210 | |
C | Minus | 1,260 | |
Normal | 1,400 | ||
| Plus (+) | 1,540 | |
D | Minus | 1,620 | |
Normal | 1,800 | ||
| Plus (+) | 1,980 |
¹@ .1” to .8” W.C. ESP
Notes:
•All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed.
•For most jobs, about 400 CFM per ton when cooling is desirable.
•Do not operate above .5” w.c. ESP in heating mode. Operating CFM between .5” and .8” w.c. is tabulated for cooling purposes only.
•Constant Fan mode is 50% of above values
GMV95 LOW-STAGE COOLING SPEEDS
GMV950453BXB
Cooling | Adjust | CFM¹ | |
Speed Tap | Tap | ||
| |||
|
|
| |
| Minus | 380* | |
A | Normal | 390 | |
| Plus (+) | 429 | |
| Minus | 468 | |
B | Normal | 520 | |
| Plus (+) | 572 | |
| Minus | 585 | |
C | Normal | 650 | |
| Plus (+) | 715 | |
| Minus | 702 | |
D | Normal | 780 | |
| Plus (+) | 858 |
GMV950704CXB
Cooling | Adjust | CFM¹ | |
Speed Tap | Tap | ||
| |||
|
|
| |
| Minus | 378* | |
A | Normal | 390 | |
| Plus (+) | 429 | |
| Minus | 468 | |
B | Normal | 520 | |
| Plus (+) | 572 | |
| Minus | 644 | |
C | Normal | 715 | |
| Plus (+) | 787 | |
| Minus | 836 | |
D | Normal | 929 | |
| Plus (+) | 1,022 |
GMV950905DXB
Cooling | Adjust | CFM¹ | |
Speed Tap | Tap | ||
| |||
|
|
| |
| Minus | 513* | |
A | Normal | 520 | |
| Plus (+) | 572 | |
| Minus | 644 | |
B | Normal | 715 | |
| Plus (+) | 787 | |
| Minus | 819 | |
C | Normal | 910 | |
| Plus (+) | 1,001 | |
| Minus | 1,053 | |
D | Normal | 1,170 | |
| Plus (+) | 1,287 |
GMV951155DXB
Cooling | Adjust |
| |
Speed | CFM¹ | ||
Tap | |||
Tap |
| ||
|
| ||
| Minus | 514* | |
A | Normal | 520 | |
| Plus (+) | 572 | |
| Minus | 644 | |
B | Normal | 715 | |
| Plus (+) | 787 | |
| Minus | 819 | |
C | Normal | 910 | |
| Plus (+) | 1,001 | |
| Minus | 1,053 | |
D | Normal | 1,170 | |
| Plus (+) | 1,287 |
¹@ .1” to .8” W.C. ESP
Notes:
•All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed.
•For most jobs, about 400 CFM per ton when cooling is desirable.
•Do not operate above .5” w.c. ESP in heating mode. Operating CFM between .5” and .8” w.c. is tabulated for cooling purposes only.
6 | www.goodmanmfg.com | |
|
|
|