SPLIT SYSTEM HEATING PERFORMANCE

EXPANDED PERFORMANCE DATA

MODEL: G/VSZ130421A* / AR*F36421**

 

 

 

 

 

 

 

 

 

HEATING OPERATION

 

 

 

 

 

 

 

Outdoor Am bie nt Te m pe rature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

65

60

55

50

47

45

40

35

30

25

20

17

15

10

5

0

-5

-10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MBh

50.3

47.6

44.8

41.9

40.0

38.8

36.0

33.2

29.9

27.6

25.4

24.0

23.1

20.7

18.4

16.0

13.7

11.2

DT

34.5

32.6

30.7

28.7

27.4

26.6

24.7

22.8

20.5

18.9

17.4

16.5

15.9

14.2

12.6

11.0

9.4

7.7

KW

3.60

3.53

3.46

3.39

3.35

3.32

3.25

3.18

3.24

3.16

3.09

3.05

3.02

2.95

2.88

2.80

2.73

2.66

A MPS

16.9

15.6

14.5

13.6

13.1

12.9

12.1

11.5

10.9

10.4

9.9

9.7

9.5

9.0

8.4

7.9

7.2

6.4

COP

4.09

3.95

3.79

3.62

3.49

3.42

3.24

3.05

2.70

2.55

2.40

2.30

2.24

2.06

1.87

1.67

1.47

1.23

EER

14.0

13.5

12.9

12.4

11.9

11.7

11.1

10.4

9.2

8.7

8.2

7.9

7.6

7.0

6.4

5.7

5.0

4.2

HI PR

368

353

340

325

317

311

299

287

275

262

252

246

242

232

223

214

207

199

LO PR

129

119

112

103

97

93

86

76

69

62

54

50

49

41

35

30

26

20

MODEL: G/VSZ130481A* /AR*F48601**

 

 

 

 

 

 

 

 

 

HEATING OPERATION

 

 

 

 

 

 

 

Outdoor Ambient Temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

65

60

55

50

47

45

40

35

30

25

20

17

15

10

5

0

-5

-10

MBh

55.3

52.4

49.3

46.1

44.0

42.6

39.6

36.5

33.6

31.1

28.6

27.0

26.0

23.3

20.7

18.0

15.4

12.6

DELTA T

32.0

30.3

28.5

26.7

25.5

24.7

22.9

21.1

19.5

18.0

16.5

15.6

15.0

13.5

12.0

10.4

8.9

7.3

KW

3.93

3.87

3.80

3.73

3.69

3.66

3.59

3.52

3.37

3.30

3.23

3.19

3.17

3.10

3.04

2.97

2.90

2.84

AMPS

18.2

16.8

15.7

14.8

14.3

14.0

13.2

12.5

12.0

11.4

10.9

10.6

10.5

9.9

9.3

8.7

8.1

7.3

COP

4.11

3.96

3.80

3.62

3.49

3.41

3.23

3.03

2.93

2.76

2.59

2.47

2.40

2.20

1.99

1.78

1.55

1.30

EER

14.1

13.5

13.0

12.4

11.9

11.7

11.0

10.4

10.0

9.4

8.8

8.5

8.2

7.5

6.8

6.1

5.3

4.4

HI PR

380

364

350

335

327

321

308

296

284

271

260

254

249

240

231

221

213

206

LO PR

129

119

112

103

97

93

86

76

69

62

54

50

49

41

35

30

26

20

MODEL: G/VSZ130601A* / AR*F48601**

 

 

 

 

 

 

 

 

 

HEATING OPERATION

 

 

 

 

 

 

 

Outdoor Ambient Temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

65

60

55

50

47

45

40

35

30

25

20

17

15

10

5

0

-5

-10

MBh

72.9

69.0

65.0

60.7

58.0

56.2

52.2

48.1

44.9

41.4

38.1

36.0

34.7

31.1

27.6

24.0

20.5

16.8

DELTA T

37.5

35.5

33.4

31.2

29.8

28.9

26.9

24.8

23.1

21.3

19.6

18.5

17.8

16.0

14.2

12.4

10.6

8.6

KW

5.21

5.11

5.01

4.92

4.86

4.82

4.72

4.63

4.66

4.56

4.46

4.40

4.36

4.26

4.16

4.06

3.96

3.86

AMPS

24.0

22.2

20.7

19.5

18.8

18.4

17.3

16.4

15.7

15.0

14.2

13.9

13.7

13.0

12.1

11.3

10.5

9.4

COP

4.10

3.95

3.79

3.62

3.49

3.41

3.23

3.05

2.82

2.66

2.50

2.40

2.33

2.14

1.94

1.73

1.52

1.28

EER

14.0

13.5

13.0

12.4

11.9

11.7

11.1

10.4

9.6

9.1

8.6

8.2

8.0

7.3

6.6

5.9

5.2

4.4

HI PR

416

399

383

367

358

351

338

324

310

296

285

278

273

262

252

242

233

225

LO PR

133

123

115

106

100

96

89

79

71

64

56

52

50

42

37

31

27

21

High pressure is measured at the liquid service valve (the smaller valve). Low pressure is measured at the gauge port connection.

Calculations are based on nominal CFM and 70 °F indoor dry bulb.

AMPS = Outdoor unit amps (comp.+fan) KW = Total system power

*Note: Shaded area is AHRI Rating Conditions at 47° outdoor ambient temberature

39

Page 39
Image 39
Goodman Mfg GSZ/VSZ 13 SEER service manual Expanded Performance Data, Outdoor Am bie nt Te m pe rature