Wiring is subject to change, always refer to

CONTROLBOX

DC

 

H

DF2

 

BK

 

V

LVDR

 

D

BK

 

R

 

DF1

 

 

C Y O O W2 R R DFT

BL OR WH RD

YL BK RD RD

BL/PK

YL/PK

 

 

 

 

 

LVJB

RD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WH

 

 

W2

 

NOTE1

 

 

 

OR

 

 

O

 

 

 

 

 

 

 

 

 

 

 

BL/PK

 

Y

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BL

 

 

C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COLORCODE

BK---------------

BLACK

BL/PK----------

BLUE/PINKSTRIPE

BR---------------

BROWN

OR---------------

ORANGE

PU---------------

PURPLE

RD---------------

RED

WH--------------

WHITE

YL---------------

YELLOW

YL/PK------------

YELLOW/PINKSTRIPE

OUTDOORPOWERSUPPLY

SEERATINGPLATE

T1

 

 

 

 

 

T3

L1

 

 

 

T2

L2

C L3

C

 

 

 

C

 

 

T2

 

 

 

COMP

 

 

 

T1

 

 

 

 

 

 

 

 

 

T3

FC

 

DF1

 

 

 

 

 

 

HVDR

 

 

 

 

 

 

DF2

 

 

 

 

 

 

 

IO

A

U

X

 

 

 

 

 

 

 

 

 

 

 

HIGHVOLTAGE! DISCONNECT UNIT.MULTIPLE DO SO MAY

WIRING DIAGRAMS

the wiring diagram on the unit for the most up-to-date wiring.

43

 

 

 

 

 

 

 

 

 

 

 

WIRINGCODE

 

 

 

 

 

 

 

 

 

 

 

 

FACTORYWIRING

 

 

 

 

 

 

BK

BK

YL

 

 

 

HIGHVOLTAGE

 

 

 

 

 

 

 

 

 

LOWVOLTAGE

 

 

 

 

 

 

BL

 

BK

RD

 

 

 

 

 

 

 

 

 

 

 

OPTIONALHIGHVOLTAGE

 

 

 

 

 

BL

 

 

T2

 

RD

 

 

 

 

 

 

 

T1

T3

 

FIELDWIRING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YL

L1

L2

L3

 

 

HIGHVOLTAGE

R

 

 

 

 

 

YL/PK

BK

BK

C

 

 

LOWVOLTAGE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RD

 

 

R

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PU

 

 

 

 

 

 

 

 

 

 

 

 

 

FC

BR

COMPONENTCODE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C---------------CONTACTOR

 

BL/PK

 

 

 

 

 

 

 

 

 

 

CH-------------CRANKCASEHEATER

 

 

 

 

 

 

 

 

 

 

 

CM------------OUTDOORFANMOTOR

R

 

BL/PK

 

 

 

 

 

 

 

 

 

COMP--------COMPRESSOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DC-------------DEFROSTCONTROL

 

 

YL BK

RD

BK

 

BK

 

 

 

 

 

DFT-----------DEFROSTTHERMOSTAT

 

 

RVC

 

 

 

 

 

HPS-------------HIGHPRESSURESWITCH

 

 

 

 

 

 

 

 

 

 

 

 

COMP

 

 

 

 

 

 

 

 

FC-------------FANCAPACITOR

 

 

 

 

 

 

 

 

 

 

 

 

 

HPS

T1

T3

 

 

 

 

 

EQUIPMENTGROUND

HVDR--------HIGHVOLTAGEDEFROSTRELAY

 

 

 

 

 

 

 

 

USECOPPER

 

IO--------------INTERNALOVERLOAD

 

 

BR

 

 

 

 

 

 

 

 

 

 

PU BK

 

RD

DFT

 

 

 

CONDUCTORSONLY

LPS------------LOWPRESSURESWITCH

 

 

 

RD

 

 

 

 

 

 

 

LVDR---------LOWVOLTAGEDEFROSTRELAY

 

 

 

 

 

 

 

 

 

 

 

 

MAIN

 

 

 

 

 

 

 

 

 

 

LVJB----------LOWVOLTAGE JUNCTIONBOX

 

AUX

 

 

 

 

 

 

 

 

 

 

RVC-----------REVERSINGVALVECOIL

 

 

T2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IO

 

 

YL/PK

LPS

YL/PK

 

 

 

 

CONTROLSSHOWNWITHTHERMOSTATIN'OFF'POSITION.

 

 

 

 

 

 

 

 

 

BK

BK

 

 

 

 

 

 

 

 

 

 

 

 

CH

 

 

 

 

 

 

 

 

 

 

CM

 

(IFUSED)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

M

 

CM

A

 

 

I

 

 

 

 

N

 

 

 

 

CH

 

 

 

 

(IFUSED)

 

DFT

 

 

 

 

 

DFT

DC

C

 

Y

 

 

 

 

LVDR

 

 

 

 

W2

 

 

 

O

 

 

 

RVC

 

 

 

 

O

 

 

LPS

C

 

 

 

 

HPS

C

O W2

INDOORPOWER

SUPPLY

NOTES:

1)TOINDOORUNITLOWVOLTAGE TERMINALBLOCK&INDOOR THERMOSTAT.

USEN.E.C.CLASS2WIRE

0140R00162REV.B

CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH

ALL POWER BEFORE SERVICING OR INSTALLING THIS POWER SOURCES MAY BE PRESENT. FAILURE TO

.

 

GSZ130[36-60][3,4]A*

Page 43
Image 43