![](/images/new-backgrounds/1177955/17795559x1.webp)
Run
Dispense Mode
Run Screen
Use the Run screen to dispense a recipe or individual fluids. The Run screen displays either Recipe Dispense or Fluid Dispense, depending on which Dispense Mode was selected in System setup.
Idle, Dispense, and Alarm Status
In each of the fluid columns, under the Fluid panel number, is a status line, which shows the status of the associated fluid panel. The three possible statuses are:
Idle — fluid panel is idle (not dispensing).
Dispense — fluid panel is dispensing.
Alarm — controller has detected the fluid panel has an alarm condition. To view alarm information, press the right arrow key twice to move to Alarm screen. Refer to page 33.
Status line
|
|
|
| RECIPE |
| DISPENSE | ID# |
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
| |||
|
|
|
| Fluid 1 | Fluid 2 | Fluid 3 | |||
|
|
|
| ||||||
|
|
|
| ||||||
|
|
|
| ||||||
|
|
|
| ||||||
|
|
|
| Idle | Idle | Idle | |||
|
|
|
| ||||||
Target | 005.00 ltr | 050.00 ltr | 010.10 ltr | ||||||
Actual | 5.00 ltr | 51.00 ltr | 10.00 ltr | ||||||
Tolerance % | 5 |
| 5 | 5 |
|
| |||
Difference % | 0 |
| +2 |
|
| ||||
|
|
|
|
|
|
|
|
| |
Run |
| Totals | Alarms |
|
|
| |||
|
|
|
|
|
|
|
|
|
|
| Start |
STOP |
|
AUTO ON | Dispense |
DISPENSE |
|
| Switch AUTO |
DISPENSE |
|
START |
|
Recipe Dispense
Recipe Dispense displays in the Run screen if “Recipe” is selected as the Dispense Mode. Recipe Dispense is used to dispense a set amount of fluid, typically from more than one fluid panel simultaneously.
1.Place the dispense lines into the receptacle(s) you want to dispense into.
2.Set the Operator Station dispense switch to AUTO.
3.Type the desired recipe number
The Target value is set in Recipe Setup. You cannot change it in the Run screen.
4.Type a 4 digit ID# if desired.
5.Press the Start button on the Controller or on the Remote Operator Station to begin dispensing the recipe.
6.As the fluids dispense, their statuses on the screen change from Idle to Dispense and the amounts dis- pensed appear in the Actual row.
START | 7. Each fluid panel stops dispensing when its individual |
| Target is reached. |
ti1359a
30 | 309301G |