Dispense Mode
Alarms
Alarm History Screen
Press the left or right arrow key to select Alarms. This screen summarizes the last five alarms that have occurred.
ALARMS
Date | Time | Description | Recipe | Fluid |
03/09 | 9:39 | Invalid | 10 | 1 |
03/08 | 14:32 | Out of Tolerance | 0 | 1 |
03/05 | 15:01 | Timeout | 6 | 2 |
03/05 | 8:12 | Out of Tolerance | 6 | 2 |
03/02 | 10:59 | Invalid | 0 | 3 |
Press Print key to print an Alarms Report.
Run
Totals
Alarms
Out of Tolerance Alarm
This alarm occurs when the current actual dispense is either less than target – tolerance or greater than target + tolerance.
Dispense Timeout Alarm
The controller stops an active dispense and initiates this alarm when the current dispense is not finished by the end of the Timeout. Timeout is a value entered during Fluid Setup (page 27).
Invalid K-factor Alarm
This alarm occurs if the meter
Memory Failure Alarm
This alarm occurs when the memory has been replaced but not programmed or when the memory has become corrupt.
See page 36 for alarm troubleshooting information.