Graco 244561 Alarm History Screen, Out of Tolerance Alarm, Dispense Timeout Alarm

Models: 244561

1 74
Download 74 pages 24.05 Kb
Page 33
Image 33

Dispense Mode

Alarms

Alarm History Screen

Press the left or right arrow key to select Alarms. This screen summarizes the last five alarms that have occurred.

ALARMS

Date

Time

Description

Recipe

Fluid

03/09

9:39

Invalid K-factor

10

1

03/08

14:32

Out of Tolerance

0

1

03/05

15:01

Timeout

6

2

03/05

8:12

Out of Tolerance

6

2

03/02

10:59

Invalid K-factor

0

3

Press Print key to print an Alarms Report.

Run

Totals

Alarms

Print

Out of Tolerance Alarm

This alarm occurs when the current actual dispense is either less than target – tolerance or greater than target + tolerance.

Dispense Timeout Alarm

The controller stops an active dispense and initiates this alarm when the current dispense is not finished by the end of the Timeout. Timeout is a value entered during Fluid Setup (page 27).

Invalid K-factor Alarm

This alarm occurs if the meter K-factor is set to zero (00.000).

Memory Failure Alarm

This alarm occurs when the memory has been replaced but not programmed or when the memory has become corrupt.

See page 36 for alarm troubleshooting information.

309301G

33

Page 33
Image 33
Graco 244561 Alarm History Screen, Out of Tolerance Alarm, Dispense Timeout Alarm, Invalid K-factor Alarm