Servicing Fluid Panel 246838
Replacing Solenoid or Dispense Valve
1.If necessary, purge ProDispense system (page 35).
2.Relieve pressure (page 24) and turn off controller power switch.
3.Follow steps
4.Disconnect fluid lines from the meter and dispense valve. Disconnect air line from the solenoid.
5.Remove dispense valve and solenoid assembly from the fluid panel.
Remove fittings from old components and reinstall in new components as needed.
6.If replacing dispense valve (19):
a.Place flats of the solenoid (3) in a vice.
b.Unscrew dispense valve (19) from the solenoid (3).
c.Screw new dispense valve into connector (C).
7.If replacing solenoid (3):
a.Place flats of the solenoid (3) in a vice and unscrew dispense valve.
b.Screw new solenoid (3) into connector (B).
8.Follow steps
9.Connect fluid lines to the meter and dispense valve. Connect air line to the solenoid.
10.Load fluid at low pressure and check for leaks. Tighten fittings as needed.
52 | 309301G |