Graco 3A2587H important safety instructions Starting a New Job Or Refilling the Material Cup

Models: 3A2587H

1 32
Download 32 pages 32.47 Kb
Page 11
Image 11

Starting a New Job

(or Refilling the Material Cup)

1.Engage trigger lock and put prime/spray valve UP to release pressure.

Starting a New Job (or Refilling the Material Cup)

If sprayer fails to prime, try one of the steps below:

1.Use the Pump Armor storage/startup tool to clean the inlet valve fitting. See Storage, page 17.

ti18912a

ti16700a

ti14999a

ti14994a

 

2.Install material cup liner, fill with material, and thread onto sprayer.

ti15474a

ti15551a

3.To fill sprayer with fluid, disengage trigger lock and trigger sprayer for 10 seconds. Then release trigger and put prime/spray valve DOWN to spray position.

ti19536a

2.Clean air vent holes. See Shutdown and Cleaning, page 15.

Use a soft brush to clean the black rubber inlet seal. If air vent holes become clogged, use a paper clip to clean the holes.

ti14995a

ti15418ati16716a

ti15425a

ti18913a

 

ti16701a

4. Reverse spray tip to UNCLOG position. Pull trigger

and release.

ti17323a

 

ti14777a

ti15012a

5. Put prime/spray valve UP to release pressure. Then rotate spray tip back to spray position.

NOTE: Failure to perform this operation could result in poor spray pattern.

ti16700a

ti14778a

ti17326a