Shutdown and Cleaning

The motor has a built-in feature to protect itself from overuse. If the motor stops, the thermal switch has tripped. Do not return sprayer to store. The motor will operate normally after cooling for 20-30 minutes.

For best results, do not spray more than one cup of water through the tip while cleaning. If more flushing is needed, remove the tip from the sprayer.

NOTICE

Failure to properly clean sprayer after each use will result in hardened materials, damage to the sprayer, and the war- ranty will no longer be valid. Do not store solvents other than mineral spirits in sprayer. Always flush with Graco Pump Armor prior to storage.

Flushing Sprayer

Use only water-based or mineral spirit-type materials with flash point greater than 100° F (38° C). Do not use materials which state “FLAMMABLE” on the packaging. For more information about your material, request MSDS from distributor or retailer.

Use oil-based material outdoors or in a well-ventilated indoor area with a flow of fresh air.

Keep spray area well-ventilated. Keep a good supply of fresh air moving through the area.

NOTICE

Protect the internal parts of this sprayer from water. Do not submerge the sprayer in cleaning fluid. Openings in shroud allow cooling of mechanical parts and electronics inside. If water or cleaning fluid gets into these openings, the sprayer could malfunction or become permanently dam- aged.

1.Engage trigger lock and pull prime/spray valve UP to release pressure.

ti18912a

ti16700a

i14994

2.Remove material cup and return excess material to proper container. If used, properly dispose the material cup liner.

Shutdown and Cleaning

3.Remove flexible suction tube as shown below.

ti19034a

NOTICE

When removing flexible suction tube from sprayer, make sure to pull directly on top fitting of flexible suction tube. The tube will become damaged if pulled from bottom or on flexi- ble portion.

4.Use screwdriver to pry flexible suction tube strainer from flexible suction tube.

ti18952a

5.Clean flexible suction tube and suction tube strainer with water (or flushing fluid) and a brush every time you flush the sprayer. Reconnect flexible suction tube and suction tube strainer and orient as shown.

ti18859a

ti19035a

 

ti19463a

6.Clean material cup if not using a liner, and fill with water or appropriate flushing fluid.

ti15017a

7.Reconnect material cup and shake sprayer to move clean water around and clean all areas inside of cup.