Starting a New Job (or Refilling the Material Cup)
Starting a New Job
(or Refilling the Material Cup)
1.Engage trigger lock and put prime/spray valve UP to release pressure.
ti18866a | ti16700a | |
ti14999a | ||
ti14994a |
2.Install material cup liner, fill with material, and thread onto sprayer.
ti15474a
ti18868a
3.To fill sprayer with fluid, disengage trigger lock and trigger sprayer for 10 seconds. Then release trigger and put prime/spray valve DOWN to spray position.
ti18874a |
|
|
ti14995a | ti15418a ti16716a | ti15425a |
|
| ti16701a |
4.Reverse spray tip to UNCLOG position, pull trigger and release.
ti14991a | ti14991a | ti14985a |
| ti16713a | |
|
|
5.Put prime/spray valve UP to release pressure. Then rotate spray tip back to spray position.
NOTE: Failure to perform this operation could result in poor spray pattern.
ti16700a ti16992a
If sprayer fails to prime, try one of the steps below:
1.Use the Pump Armor storage/startup tool to clean the inlet valve fitting. See Storage, page 17.
2.Clean air vent holes or the air vent valve, depending on model. See Shutdown and Clean- ing, page 15.
Model 16N660: Use a soft brush to clean the black rubber inlet seal. If air vent holes become clogged, use a paper clip to clean the holes.
ti17323a | ti17326a |
For all other units: Remove air vent valve, clean, and reinstall.
ti18876a
3A2589D | 11 |