Shutdown and Cleaning
Shutdown and Cleaning
NOTICE
Failure to properly clean sprayer after each use will result in hardened materials, damage to the sprayer, and the warranty will no longer be valid. Do not store solvents other than mineral spirits in sprayer. Always flush with Graco Pump Armor prior to storage.
Flushing Sprayer
Use only
For more information about your material, request MSDS from distributor or retailer.
Spraying certain materials may cause static
Use
Keep spray area
NOTICE
Protect the internal parts of this sprayer from water. Do not submerge the sprayer in cleaning fluid. Openings in shroud allow cooling of mechanical parts and electron- ics inside. If water or cleaning fluid gets into these open- ings, the sprayer could malfunction or become permanently damaged.
1.Engage trigger lock and pull prime/spray valve UP to release pressure.
2.Remove material cup and return excess material to proper container. If used, properly dispose the material cup liner.
3.Remove flexible suction tube as shown below.
ti19033a
NOTICE
When removing flexible suction tube from sprayer, make sure to pull directly on top fitting of flexible suction tube. Flexible suction tube will become damaged if pulled from bottom or on flexible portion.
4.Use screwdriver to pry suction tube strainer from flexi- ble suction tube.
ti18952a
5.Clean flexible suction tube and suction tube strainer with water (or flushing fluid) and a brush every time you flush the sprayer. Reconnect flexible suction tube and suction tube strainer and orient as shown.
ti18859a | ti19467a |
| |
| ti15002a |
ti19463a
6.Clean material cup if not using a liner, and fill with water or appropriate flushing fluid.
ti18866a | ti16700a |
ti14999a
ti15001a