Graco 3A2589D important safety instructions Shutdown and Cleaning, Flushing Sprayer

Models: 3A2589D

1 34
Download 34 pages 6.77 Kb
Page 15
Image 15
Shutdown and Cleaning

Shutdown and Cleaning

Shutdown and Cleaning

NOTICE

Failure to properly clean sprayer after each use will result in hardened materials, damage to the sprayer, and the warranty will no longer be valid. Do not store solvents other than mineral spirits in sprayer. Always flush with Graco Pump Armor prior to storage.

Flushing Sprayer

Use only water-based or mineral spirit-type materials with flash point greater than 100° F (38° C). Do not use materials which state “FLAMMABLE” on the packaging.

For more information about your material, request MSDS from distributor or retailer.

Spraying certain materials may cause static build-up in the sprayer that can result in static shock to the user. If this occurs, first ensure the material has a flash point greater than 100° F (38° C) and does not state that it is FLAMMABLE anywhere on the package. If still feeling a static shock, the material likely contains a non-mineral spirits fluid such as, but not limited to, xylene, toluene, or naphtha, which can build up static. Switch to an alterna- tive material.

Use oil-based material outdoors or in a well-ventilated indoor area with a flow of fresh air.

Keep spray area well-ventilated. Keep a good supply of fresh air moving through the area.

NOTICE

Protect the internal parts of this sprayer from water. Do not submerge the sprayer in cleaning fluid. Openings in shroud allow cooling of mechanical parts and electron- ics inside. If water or cleaning fluid gets into these open- ings, the sprayer could malfunction or become permanently damaged.

1.Engage trigger lock and pull prime/spray valve UP to release pressure.

2.Remove material cup and return excess material to proper container. If used, properly dispose the material cup liner.

3.Remove flexible suction tube as shown below.

ti19033a

NOTICE

When removing flexible suction tube from sprayer, make sure to pull directly on top fitting of flexible suction tube. Flexible suction tube will become damaged if pulled from bottom or on flexible portion.

4.Use screwdriver to pry suction tube strainer from flexi- ble suction tube.

ti18952a

5.Clean flexible suction tube and suction tube strainer with water (or flushing fluid) and a brush every time you flush the sprayer. Reconnect flexible suction tube and suction tube strainer and orient as shown.

ti18859a

ti19467a

 

 

ti15002a

Flushing SprayerManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background ti19463a

6.Clean material cup if not using a liner, and fill with water or appropriate flushing fluid.

ti18866a

ti16700a

ti14999a

ti15001a

3A2589D

15

Page 15
Image 15