Troubleshooting

Troubleshooting

1.

2.

Follow Pressure Relief Procedure, page 18,

before checking or repairing gun.

Check all possible problems and causes before

disassembling gun.

CAUTION

To prevent cross-contamination of the gun’s wetted parts, do not interchange A component (isocyanate) and B component (resin) parts.

PROBLEM

CAUSE

SOLUTION

 

 

 

 

 

 

Gun does not fully actuate when trig-

Piston safety lock engaged.

Disengage piston safety lock, page

gered.

 

12.

 

 

 

 

Plugged muffler (22).

Clean, page 22.

 

 

 

 

Damaged air valve o-rings (24).

Replace, page 44.

 

 

 

Fluid does not spray when gun is fully

Closed fluid valves (12b).

Open.

actuated.

 

 

 

 

 

 

Plugged impingement ports.

Clean, page 23.

 

 

 

 

Plugged check valves (36).

Clean, page 41.

 

 

 

Gun actuates slowly or with delayed

Plugged muffler (22).

Clean, page 22.

action.

 

 

 

 

 

 

Damaged piston o-rings (16, 19).

Replace, page 42.

 

 

 

 

Dirty air valve, or damaged o-rings

Clean air valve or replace o-rings,

 

(24).

page 44.

 

 

 

 

Mix module nut (25) too tight.

Loosen nut, then retighten, page 37.

 

 

 

 

Incorrect purge rod adjustment.

Adjust Purge Rod, page 15.

 

 

 

 

Loose lock ring (11).

Tighten, use tool if necessary. Adjust

 

 

Purge Rod, page 15.

 

 

 

Purge rod will not actuate.

No air pressure.

Connect air supply.

 

 

 

 

Low air pressure.

Set air pressure above 80 psi (0.56

 

 

MPa, 5.6 bar).

 

 

 

 

Buildup on purge rod (31).

See Clean Purge Rod, page 27.

 

 

 

30

309856P

Page 30
Image 30
Graco Inc TI3840a, 309856P, 2004230905 important safety instructions Troubleshooting, See Clean Purge Rod