Troubleshooting
Troubleshooting
1.
2.
Follow Pressure Relief Procedure, page 18,
before checking or repairing gun.
Check all possible problems and causes before
disassembling gun.
CAUTION
To prevent
PROBLEM | CAUSE | SOLUTION |
|
|
|
|
|
|
Gun does not fully actuate when trig- | Piston safety lock engaged. | Disengage piston safety lock, page |
gered. |
| 12. |
|
|
|
| Plugged muffler (22). | Clean, page 22. |
|
|
|
| Damaged air valve | Replace, page 44. |
|
|
|
Fluid does not spray when gun is fully | Closed fluid valves (12b). | Open. |
actuated. |
|
|
|
|
|
| Plugged impingement ports. | Clean, page 23. |
|
|
|
| Plugged check valves (36). | Clean, page 41. |
|
|
|
Gun actuates slowly or with delayed | Plugged muffler (22). | Clean, page 22. |
action. |
|
|
|
|
|
| Damaged piston | Replace, page 42. |
|
|
|
| Dirty air valve, or damaged | Clean air valve or replace |
| (24). | page 44. |
|
|
|
| Mix module nut (25) too tight. | Loosen nut, then retighten, page 37. |
|
|
|
| Incorrect purge rod adjustment. | Adjust Purge Rod, page 15. |
|
|
|
| Loose lock ring (11). | Tighten, use tool if necessary. Adjust |
|
| Purge Rod, page 15. |
|
|
|
Purge rod will not actuate. | No air pressure. | Connect air supply. |
|
|
|
| Low air pressure. | Set air pressure above 80 psi (0.56 |
|
| MPa, 5.6 bar). |
|
|
|
| Buildup on purge rod (31). | See Clean Purge Rod, page 27. |
|
|
|
30 | 309856P |