Adjust Purge Rod

Adjust Purge Rod

1. Engage piston safety lock, page 12.

TI3850a

2. Close fluid valves A and B.

3.

4.

Connect air supply and open air valve (U).

Adjust purge rod with nut driver clockwise until it

just touches CeramTip, then back off 1/8-1/4 turn.

1/8-1/4 Turn

BU

TI3837a

A

TI3829a

TI3828a

Be sure to back out purge rod 1-2 turns before changing CeramTips or mix modules. Readjust purge rod after replacing CeramTips or mix modules.