Daily Gun Maintenance

Troubleshooting

Problem

Cause

Solution

 

 

 

Spray Pattern

Normal pattern.

No action necessary.

Right

 

 

Spray Pattern

Dirty or damaged air cap or fluid

Rotate air cap 180°.

 

nozzle.

If pattern follows air cap, problem is in air

 

 

 

 

cap (13). Clean and inspect. If pattern is

 

 

not corrected, replace air cap.

Wrong

 

If pattern does not follow the air cap, the

Heavy top

 

 

problem is with the fluid nozzle. Clean

or bottom

 

 

and inspect the nozzle. If the pattern is

 

 

 

 

not corrected, replace nozzle.

Spray Pattern

Pressure too high for viscosity of

Reduce air pressure and increase mate-

 

material being sprayed.

rial viscosity.

 

 

Correct pattern by narrowing fan size with

Wrong

 

fluid control valve (8).

Split pattern

 

 

Spray Pattern

Dirty or distorted air horn holes.

Clean and inspect air cap. If pattern is not

 

 

corrected, replace air cap.

Wrong

 

 

Gun spitting

Air getting into paint stream.

Check if cup is empty and fill.

 

 

Tighten fluid nozzle (11).

 

 

Check and tighten needle packing nut (17).

 

 

Check fluid nozzle (11) for damage.

 

 

Replace fluid inlet gasket (3)

 

Damaged fluid nozzle seal (19).

Replace seal (19).

Will not spray

Cup is empty.

Fill cup.

 

Fluid control valve (8) turned too

Adjust valve (8) counterclockwise.

 

far clockwise.

 