SECTION 2: CIRCUIT REQUIREMENTS

G0449

 

G0450 at 220V

 

 

 

 

 

 

Serious personal injury could occur if you connect the machine to the power source before you have completed the set up pro- cess. DO NOT connect the machine to the power source until instructed to do so.

Amperage Draw

The 10 HP motor on the Model G0449 will draw the following amps:

Main Motor

............................................44

Amps

Feed Motor

...........................................21/2

Amps

Circuit Requirements

Only connect your machine to a circuit that meets the requirements below. Always check to see if the wires and circuit breaker in your circuit are capable of handling the amperage draw from your machine, as well as any other machines that could be operating on the same circuit. If you are unsure, consult a qualified electrician.

Minimum Circuit Requirement

60 Amp

Minimum Cord Requirements

A cord is not provided with your machine. For 220V single-phase operation, use the following type of cord (not to exceed 50 ft.):

Cord

3 wire

Gauge

4 Gauge

A fire may occur if your particular electrical configuration does not comply with local and state codes. The best way to ensure compli- ance is to check with your local municipality or a qualified electrician.

G0449/G0450 37" Drum Sander

Serious personal injury could occur if you connect your machine to the power source before you have completed the set up pro- cess. DO NOT connect the machine to the power source until instructed to do so.

220V Pre-Wired

The Model G0450 is prewired for 220V 3-phase operation, but can be rewired for 440V 3-phase operation if needed.

Amperage Draw

The Model G0450 has a 15 HP motor that will draw the following amps at 220V 3-phase:

Main Motor at 220V

...............................40

Amps

Feed Motor at 220V

.............................. 1.3

Amps

Circuit Requirements

Only connect your machine to a circuit that meets the requirements below. Always check to see if the wires and circuit breaker in your circuit are capable of handling the amperage draw from your machine, as well as any other machines that could be operating on the same circuit. If you are unsure, consult a qualified electrician.

Minimum Circuit Requirement 220V

60 Amp

Minimum Cord Requirements

A cord is not provided with your machine. For 220V 3-phase operation, use the following type of cord (not to exceed 50 ft.):

Cord

4 wire

Gauge

4 Gauge

-11-