Grizzly G0588/G0591 instruction manual Circuit Requirements, 220V Single-Phase

Models: G0588/G0591

1 76
Download 76 pages 34.82 Kb
Page 14
Image 14

SECTION 2: CIRCUIT REQUIREMENTS

220V Single-Phase

Serious personal injury could occur if you connect the machine to the power source before you have completed the set up pro- cess. DO NOT connect the machine to the power source until instructed to do so.

Amperage Draw

The 5 HP motor on the Model G0591 will draw the following amps:

Motor Draw at 220V

22 Amps

Minimum Circuit Requirements

Only connect your machine to a circuit that meets the requirements below. Check to see if the wires and circuit breaker in your circuit are capable of handling the amperage draw from your machine, as well as any other machines that could be operating on the same circuit. If you are unsure, consult a qualified electrician.

Minimum Circuit Requirement

25 Amp

Minimum Cord Requirements

Use the following type of cord to connect your machine to power (a cord is not provided):

Cord

3 wire

Gauge

10 Gauge

Extension Cords

We do not recommend the use of extension cords on 220V equipment. Instead, arrange the place- ment of your equipment and the installed wiring to eliminate the need for extension cords.

If you find it absolutely necessary to use an exten- sion cord at 220V with your machine, check with a qualified electrician for the correct sizing, type, and maximum possible length for your needs.

-12-

Connection Type

Recommended Plug/Receptacle....NEMA L6-30

Figure 4. NEMA L6-30 plug and receptacle.

Another option for increased safety is to hardwire your machine directly to the circuit breaker and install a locking shut-off lever near the machine as a way to quickly disconnect the power and prevent accidental starting (see Figure 5).

Grounding

In the event of an electrical short, grounding reduces the risk of electric shock. The ground- ing wire in the cord must be properly connected to the grounding prong on the plug; likewise, the outlet must be properly installed and grounded. All electrical connections must be made in accor- dance with local codes and ordinances.

Electrocution or fire could result if this machine is not grounded correctly or if your electrical con- figuration does not com- ply with local and state codes. Ensure compliance by checking with a quali- fied electrician!

G0588/G0591 12" Sliding Table Saws

Page 14
Image 14
Grizzly G0588/G0591 instruction manual Circuit Requirements, 220V Single-Phase