Power Cord
Before installing the power cord, read through SECTION 2: CIRCUIT REQUIREMENTS to check that your setup follows the safety and cir- cuit requirements, and the power cord and power disconnect or plug that you have chosen meet the requirements for this machine.
Components and Hardware Needed: | Qty |
Power Cord (Not Included) | 1 |
To connect the saw to the power source:
1.Open the terminal box shown in Figure 47.
Figure 47. G0591 main terminal box.
2.Feed the power cord through the strain relief on the bottom of the box shown in Figure 47, tighten the strain relief, connect the cord to the terminals, and close the terminal box.
Note: For Model G0588 only; When using a phase converter, connect the manufactured power leg to the S terminal. The S terminal can handle power fluctuation because it is wired directly to the motor. The other wires connect to the transformer and must be con- sistent to prevent damage.
3.Shut off the main power at the power source circuit breaker and install the cord to the disconnect switch or plug.
Test Run
Now that the machine is connected to the power source, it is important to perform a test run to make sure all the controls are working properly.
Before starting the saw, make sure you have performed the preceding assembly and adjustment instructions, and you have read through the rest of the manual and are familiar with the various functions and safety issues associated with this machine. Failure to follow this warning could result in serious personal injury or even death!
To test run the saw:
1.Put on safety glasses and make sure any bystanders are out of the way and also wear- ing safety glasses.
2.Rotate both of the red EMERGENCY STOP buttons until they spring up.
3.Press the ON button.
G0588/G0591 12" Sliding Table Saws |