4.Remove the screws that secure the lower blade guard (Figure 81) and set the guard in the bottom of the cabinet.

3.Rotate the belt tension arm shown in Figure 82 and slide the flat belt off of the roller.

Figure 81. Lower blade guard removal.

5.Remove the old V-belt set and replace them with a new V-belt set.

Note: The motor V-belts should always be replaced as a matched set to ensure maxi- mum belt longevity and power transmission.

6.Tighten the tension bolt until the belts deflect between a 14" and a 12" when pressed firmly in the center of each V-belt.

7.Replace the lower blade guard.

8.Close and secure the motor cabinet door.

Note: Re-tension the new V-belts after the initial 10 hours of use.

To change the scoring blade arbor flat belt:

1.Disconnect the saw from the power source!

2.Move the blade tilt to 45˚, raise the main blade all the way up, and open the motor cabinet door.

Spring Arm

Figure 82. Scoring blade belt tension arm.

4.Remove the old flat belt and replace it with a new flat belt.

5.Close and secure the motor cabinet door.