Verify Configuration

A number of configuration changes may result in an invalid configuration. If you are in doubt about the configuration, restore the FCR200 to the factory default configuration and proceed to configure the unit a step at a time, verifying the functionality of the configuration as changes are made.

Verify Addressing

If working in FC-to-SCSI target mode and using Indexed or SCC Addressing, try swapping to Auto Addressing to see if this solves the problem.

Verify Devices

It may be useful to connect the target devices you are attempting to use to the native interface to verify that the devices are functional. SCSI target devices can be connected to a host SCSI bus to verify they are functional.

Verify Host Configuration

In some cases, it may be that the host bus adapter or driver may not be working properly. Check the configuration of these elements. It may be useful to check the release notes for the driver provided to see if there are any specific issues or required configuration. It may also be useful to ensure that you are using a current version of the host bus adapter driver.

Verify HBA Device Driver Information

Check the HBA device driver Readme file for configuration specifics. An HBA may require a different configuration, depending on whether it is connected to a loop or a switch.

7-6 Troubleshooting