ADIC FCR 200 manual Changing the Fibre Channel-to-SCSI Mapping Mode

Models: FCR 200

1 140
Download 140 pages 14 Kb
Page 86
Image 86

When configuring Indexed addressing, the user is presented a table with the current mappings. The user can then select a table entry by FCP LUN and specify the associated BUS:TARGET:LUN. Alternately, the user can fill with one of multiple preset patterns, or with the list of currently attached SCSI devices. The user then saves these values in FLASH memory, where they are retained across future device resets or power cycles.

Changing the Fibre Channel-to-SCSI Mapping Mode

This option allows the user to select the appropriate Fibre Channel-to-SCSI mapping mode on the FCR200. The options are SCC addressing, Indexed addressing, and Auto addressing. Auto addressing allows you to assign one of three mapping priorities:

LUN priority

fills the table according to ascending

 

LUN order.

Target ID priority

Fills the table according to ascending

 

SCSI Target ID (SCSI device address

 

ID) order.

Bus Number priority

Fills the table in ascending SCSI Bus

 

Number (SCSI port ID number)

 

order.

Fibre Channel to SCSI Mapping Mode Configuration Menu

Version: X.X.XXXX

Current Fibre Channel to SCSI Mapping Mode is Auto-assigned

Bus Number Priority

1)Set to SCC

2)Set to Indexed

3)Set to Auto-assigned, LUN Priority

4)Set to Auto-assigned, Target ID Priority

5)Set to Auto-assigned, Bus Number Priority

X) Return to previous menu