Serial Port Connection

The RJ11 connector on the rear panel of the FCR200 provides an RS-232 connection that can be used to configure the FCR200, monitor diagnostic status, or to update the program stored in the FCR200’s Flash memory. A cable is provided with the unit to connect to a DB-9 serial connection. Further information on the operations allowed via the RS-232 port is provided in Chapter 6.

The RS-232 port operates with the following settings:

 

Baud Rate:

Autobaud (9600, 19200, 38400, 57600, or

 

 

115200)

 

 

Data Bits:

8

 

 

Stop Bits:

1

 

 

Parity:

None

 

Flow Control:

None

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 4-16FCR200 Serial Port

4-18 Installation

62-9301-01

Page 58
Image 58