Control Panel
A
B
D | C |
|
Figure 2. G0613 control panel.
A.ON/OFF Push Button Switch: When the cover is open, it allows access to the normal- operation ON/OFF pushbutton switch that is used to start and stop the bandsaw.
B.EMERGENCY Stop and Anti-Start Lockout Cover: When the cover is closed but not latched shut, it serves as an easy-to-find EMERGENCY STOP button with anti-start lockout. If pushed in an emergency situation, the cover pushes the OFF button and then latches shut, preventing accidental machine startup.
Note: Both bandsaws also have an auto- matic
C.Circuit Breaker: Kills power in the event of high current draw or motor overload.
D.Cutting Fluid Pump Switch: Turns the cut- ting fluid pump ON.
E | F |
G
H | I |
Figure 3. G0614 control panel.
E.ON Button: Turns the motor ON and starts the bandsaw.
F.OFF Button: Turns the motor OFF and stops the bandsaw.
G.Cutting Speed Switch: Changes the motor speed between 1725 and 3450 RPM, giving two cutting speeds of 170 and 341 FPM.
H.Cutting Fluid Pump Switch: Turns the cut- ting fluid pump ON.
I.EMERGENCY STOP/OFF Button: Kills power to the system and turns the motor OFF. Twist the button until it pops out to re- energize the system.