220V 3-Phase

(G0614)

Serious personal injury could occur if you connect your machine to the power source before you have completed the setup pro- cess. DO NOT connect the machine to the power source until instructed to do so.

Amperage Draw

The Model G0614 features a 1 HP, 220V, 3-phase motor that draws the following amps under maxi- mum load:

Motor Draw at 220V

3 Amps

Circuit Requirements

We recommend connecting your machine to a dedicated and grounded circuit that is rated for the amperage given below. Never replace a circuit breaker on an existing circuit with one of higher amperage without consulting a qualified electri- cian to ensure compliance with wiring codes. If you are unsure about the wiring codes in your area or you plan to connect your machine to a shared circuit, consult a qualified electrician.

220V 3-Phase Circuit

15 Amps

 

 

 

 

 

 

 

 

 

Figure 5. NEMA L15-20R Plug and receptacle.

G0613/14 Swivel Mast Metal Cutting Bandsaw

Grounding

In the event of an electrical short, grounding reduces the risk of electric shock. The grounding wire in the power cord must be properly connect- ed to the grounding prong on the plug; likewise, the outlet must be properly installed and ground- ed. All electrical connections must be made in accordance with local codes and ordinances.

Electrocution or fire could result if this machine is not installed correctly or the electrical installation does not comply with local and state codes. Ensure compliance by using a qualified electrician for the electrical installation!

Extension Cords

We do not recommend using an extension cord for the machine power supply. Instead, locate your machine where you can eliminate the need of an extension cord.

If you find it absolutely necessary to use an exten- sion cord, make sure the extension cord contains a ground wire, and a grounding lug.

Use at least a 10 gauge cord that does not exceed 50 feet in length!

-13-

Page 15
Image 15
Grizzly G0613 owner manual 220V 3-Phase G0614, Grounding