-12- G0613/14 Swivel Mast Metal Cutting Bandsaw
SECTION 2: CIRCUIT REQUIREMENTS

110/220V Single-

Phase (G0613)

Amperage Draw

The Model G0613 features a 110/220V motor
that is prewired for 110V and draws the following
amps under maximum load:
Motor Draw at 220V .............................7.7 Amps
Motor Draw at 110V ........................... 15.4 Amps

Circuit Requirements

We recommend connecting your machine to a
dedicated and grounded circuit that is rated for
the amperage given below. Never replace a circuit
breaker on an existing circuit with one of higher
amperage without consulting a qualified electri-
cian to ensure compliance with wiring codes. If
you are unsure about the wiring codes in your
area or you plan to connect your machine to a
shared circuit, consult a qualified electrician.
110V Circuit ...........................................20 Amps
220V Circuit ...........................................15 Amps

220V Connection

Rewire the motors according to the wiring con -
nection diagram on the inside cover of the motor
and pump junction boxes. Refer to G0613 Single
Phase 2 20V Wiring Diagram on Page 4 6 for
general wiring details. Also use the following
220V plug for your machine on a dedicated circuit
(see Figure 4):
220V Plug & Receptacle ..............................6-15

Extension Cords

Using extension cords may reduce the life of the
motor. Instead, place the machine near a power
source. If you must use an extension cord:
For 110V, use at least a 12 gauge cord that
does not exceed 50 feet in length.
For 220V, use at least a 14 gauge cord that
does not exceed 50 feet in length.
Ensure that the extension cord contains a
ground wire and plug pin.
The Model G0613 is prewired for 110V opera-
tion. If you plan to use your machine at
220V, you must rewire the motor. Refer to
the wiring diagram and consult a qualified
electrician.
Electrocution or fire could
result if this machine is
not grounded correc tly or
if your electrical configu-
ration does not comply
with local and state codes.
Ensure compliance by
checking with a qualified
electrician!
Figure 4. Recommended 220V 6-15
outlet and plug.