3.2 Installing the F terminals

To comply with the current EMC regulations, it is necessary to connect the lines leading in and out of the head-end station using F terminals.

When mounting the cassette in an STR 19-8 head-end station which is installed in a 19" cabinet, make sure the connections leading in and out for the 19" cabinet are made using F terminals.

Insert the required number of F terminals in the openings provided in the head-end station or in the 19" cabinet.

—> F terminals are not included in the scope of delivery.

Tighten the nut on the F terminal until the teeth on the lock washer have penetrated the exterior coating and a good connection is made between the housing and F terminal.

3.3 Connecting the cassette

Eject button for CA module

HF input "B"

HF input "A"

Slot for

RS 232

 

 

CA module

 

Plug the HF input cables into the HF input sockets “HF input A” 2 (channel strip “A”) and “HF input B” 1 (channel strip “B”).

Connect the head-end station to the mains power supply.