With the gate in the fully closed position and the opener retracted, swing the opener to the gate. Mark reference points for bolt holes on gate cross member through middle of gate bracket slots. The opener must be level. (Some vertical adjustment

is possible by sliding the post bracket assembly up and down.) Drill 3/8" holes into the gate cross member as marked. Fasten gate bracket to cross member using (2) 3/8" x 3" bolts, washers, lock washers, and nuts. Attach the opener to the post bracket assembly and gate bracket using clevis pins, bushings, and hairpins clips.

Fence Post

Gate Post and Gate Cross Member

 

(In Closed Position)

LEVEL

Operator

LEVEL

POST PIVOT BRACKET level with the horizontal surface of the GATE BRACKET

LEVEL

OFF OperatorSetting the Open Position Limit 120

CLOSE TIME

SET LEARN LIMIT REMOTE

Step 4

Make sure the control box power switch is OFF. Use a small screwdriver to move the Number 1 DIP switch from the factory setting (OFF / Pull-To-Open) to ON for Push-To-Open. Turn power switch ON. The control board is now configured to push the gate open.

15

 

1

ON

2

 

3

 

4

 

AUX OUT

PULL-PUSHCHARGING Manual background

MODE1 POWER

 

 

 

 

MODE2

 

 

 

 

LOCK/BEACON

 

 

 

 

LINK

 

 

 

 

18VAC

EXIT

SAFETY

EDGE

CYCLE

SOLAR

PANEL

 

ON

PULL-PUSH

1

 

2

 

 

MODE1

 

 

3

 

 

MODE2

 

 

4

 

 

LOCK/BEACON

 

 

 

 

 

 

Manual backgroundManual backgroundManual background RF

COMMON

GRN

RCVRBLK

RED

Setting the Open Position Limit

Step 1

Confirm that the power switch is in the ON position, and the gate is in the CLOSED POSITION.

Step 2

Activate your opener by pressing the entry transmitter button. Your gate should now be moving from the closed position toward the open position. Prepare to STOP gate by pressing the entry transmitter button again when the gate reaches the desired open position. This step may be repeated until desired open position is achieved. Once the desired OPEN position has been achieved, proceed to Step 3.