GTO UL325 SERIES Setting the Closed Position Limit, Step, the opener arm to the ON position

Models: UL325 SERIES

1 45
Download 45 pages 5.68 Kb
Page 28
Image 28
Setting the Closed Position Limit

Setting the Closed Position Limit

For PULL-TO-OPEN Installation

Turn the power switch on

the opener arm to the ON position

Your Mighty Mule 350 has two Limit Settings

1)OPEN Limit setting: (Gate in the OPEN POSITION / FACTORY SET &

NOT ADJUSTABLE)

The open limit setting is the fully open position.

2)CLOSED Limit setting:

The CLOSED Limit setting (gate in the CLOSED POSITION)

To achieve optimum closed position, you are required to complete the following FOUR STEPS:

Fully Open Position

Fully Closed Position

Step 1

While programming, be sure the gate is in the OPEN POSITION and

the operator is mounted upside-down with “SET LIMIT" PROGRAM BUTTON visible on the control board.

Step 2

Activate your opener by pressing the entry transmitter. Your gate should now be moving from the fully open position toward the closing position. Prepare to STOP gate when it reaches the desired closed position by pressing the entry transmitter again. The optimum CLOSED POSITION is when the gate closes firmly, without excess tension, against the gate post. The motor should run for one-half second after the gate closes against the gate post. This step may be repeated until desired close position is achieved. Once the desired CLOSE position has been achieved, proceed to step 3.

Step 3

With your gate firmly closed. Program the closed limit setting by PRESSING & HOLDING the “SET LIMIT" BUTTON on the control board for 5 seconds.

Step 4

Save the setting by pressing the transmitter and allowing the gate to return to the fully open position. YOUR CLOSED POSITION LIMIT NOW PROGRAMMED.

STATUS

MINFor PULL-TO-OPEN Installationthe opener arm to the ON position MAX

STALL FORCE

SET LIMIT Button

OFF

120

 

 

CLOSE TIME

IS

SET

 

LEARN

LIMIT

REMOTE

 

 

 

 

 

 

TESTING YOUR CLOSED LIMIT SETTING:

Press your entry transmitter and allow your gate to close. If CLOSED position is not correct or needs to be changed you will need to CLEAR your CLOSED LIMIT (see below) setting and follow steps 1 through 4 again.

CLEARING PROGRAMMED CLOSED LIMIT SETTING:

If you make a mistake and set the limit at the wrong position press your transmitter to return the gate to its fully opened position, then press and hold the "SET LIMIT" button for 5 seconds. This will clear the memory for the closed limit position. Follow Steps 1-4 again.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 