3.12 OUT-OF-SERVICE PROCEDURE

Section 3 – Maintenance

QUIETPACT™ 75D Recreational Vehicle Generator

3.12 OUT-OF-SERVICE PROCEDURE

3.12.1 REMOVAL FROM SERVICE

Prepare the generator for storage as follows:

1.Start the engine and let it run until it is thoroughly warmed up (at least five minutes), then shut off the engine.

2.While the engine is still warm from running, drain the oil completely (see Section 3.2). Refill the crankcase with the recommended oil (see Section 1.5.3).

3.Attach a tag to the engine, indicating the viscosity and classification of the oil in the crankcase.

4.Remove the battery and store it in a cool, dry room on a wooden board. Never store the battery on any concrete or earthen floor.

5.Clean and wipe the entire generator.

3.12.2 RETURN TO SERVICE

To return the unit to service after storage, proceed as follows:

1.Check the tag on the engine for oil viscosity and classification. Verify that the correct recommended oil is used in the engine (see Section 1.5.3). If nec- essary, drain and refill with the proper oil.

2.Check the state of the battery. Fill all cells of unsealed batteries to the proper level with distilled water. DO NOT USE TAP WATER IN THE BATTERY. Recharge the battery to 100 percent state of charge, or, if defective, replace the battery.

3.Clean and wipe the entire generator.

4.Reconnect the battery. Observe battery polarity. Damage may occur if the battery is connected incor- rectly.

5.Turn OFF all electrical loads. Add fuel, if necessary, and then start the engine.

6.Allow the unit to warm up thoroughly.

7.Apply electrical loads to at least 50 percent of the unit’s rated wattage capacity.

8.When the engine is thoroughly warmed up, shut it down.

9.The generator is now ready for service.