Guardian Technologies 004702-0, 004703-0, 004704-0, 004705-0, 004706-0, 004707-0 ‹ Exhaust System

Models: 004702-0, 004703-0, 004704-0, 004705-0, 004706-0, 004707-0

1 56
Download 56 pages 47.92 Kb
Page 37
Image 37
7.4TESTING UNDER LOAD

Section 7 – Post Installation

Recreational Vehicle Generators

7.4TESTING UNDER LOAD

Apply electrical loads equal to about 75 to 100 per- cent of the unit's rated wattage/amperage capacity.

Let the unit run at least 30 minutes with load applied. During this part of the test, check that the unit is not running excessively hot and that adequate cooling airflow is available. Do not allow the unit to overheat during prolonged operation.

NOTE:

The generator engine is equipped with a high tem- perature switch. The switch has normally open (N.O.) contacts. When the engine temperature is too high, switch contacts close, and the engine shuts down automatically.

THE MANUFACTURER RECOMMENDS THAT THE GENERATOR BE TESTED FOR ADEQUATE COOL- ING.

7.5INSTALLATION CHECKLIST

‹LOCATION AND SUPPORT

Generator is properly located.

Generator is properly supported.

Generator is properly restrained.

‹OPTIONAL LP GAS FUEL SYSTEM

Fuel system is properly installed and checked for leaks.

Pressure at regulator inlet is correct.

Rated flow of primary regulator is correct.

All parts are properly installed.

Fuel system is properly tested/adjusted.

‹EXHAUST SYSTEM

Exhaust system complies with all applicable codes.

Exhaust system is properly and safely installed.

‹ELECTRICAL CONNECTIONS

Connections comply with local code requirements and all National Electrical Codes.

Junction box is properly installed.

Wiring meets all standards.

All connections are correct.

Conduit is properly installed and sealed.

Generator is properly bonded to the vehicle.

‹GENERATOR COMPARTMENT

Compartment construction is proper.

Holes/Openings are vapor-sealed.

Compartment size is correct.

Compartment is vapor-sealed.

Sound insulation is correct.

Floor cutouts are properly completed.

‹BATTERY INSTALLATION

Recommended battery is installed.

Recommended cables are installed.

Cables are clean and tight.

Cables are connected properly.

Proper ventilation is provided.

Terminals are coated with anti-corrosion grease, and terminal covers are positioned.

‹COOLING AND VENTILATING AIR

Airflow is adequate.

Air inlet opening is correct.

Compensate for restrictions.

Check that installation has been tested.

‹GASOLINE FUEL SYSTEM

Fuel tank complies with all applicable codes.

Fuel system is properly installed and checked for leaks.

‹OPTIONAL ACCESSORIES

Check that remote start/stop panels (if used) are installed properly.

Check that hourmeter kit (if used) is installed properly.

Check that any other options and accessories (if used) are installed properly.

‹POST INSTALLATION TESTS

Check that all tests are completed properly.

DATE OF INSTALLATION ____________________________________________________

NAME OF INSTALLER_______________________________________________________

SIGNATURE OF INSTALLER _________________________________________________

35

Page 37
Image 37
Guardian Technologies 004702-0, 004703-0, 004704-0, 004705-0, 004706-0, 004707-0 Testing Under Load, ‹ Exhaust System