Diagnostic Repair Manual
Diagnostic Repair Manual
Electrical Formulas
Stator Winding Resistance Values / Rotor Resistance
Engine
Fuel Consumption
Mounting Dimensions
Specifications
Major Features
Part General Information
Serial Number
Introduction
Item Number
Prepackaged Transfer Switches
Transfer Switch / Load Center
Selecting a Location
Grounding the Generator
Prepackaged Installation Basics Part
System Control Interconnections
Power Source and Load Lines
Fuel Requirements
General
Meters
Visual Inspection
VOM
Measuring AC Voltage
Measuring Resistance
Measuring AC Frequency
Measuring Current
Ohms LAW
Electrical Units
Ampere
Volt
Stator Insulation Resistance Test
Insulation Resistance
Megohmmeter
Test Between Windings
Testing ALL Stator Windings to Ground
Drying the Generator
Cleaning the Generator
Rotor Insulation Resistance Test
LOW OIL Pressure Shutdown
High OIL Temperature Shutdown
Overspeed Shutdown
Overcrank Shutdown
OFF Position
Control Panel
Manual Position
Auto position
To Select Automatic Operation
SET Exercise Switch
Manual Transfer to Standby Manual Startup
Protection Systems
Manual Shutdown and Retransfer Back to Utility
Automatic Operating Sequences
Automatic Operating Parameters
SEQ. Condition Action SENSOR, Timer or Other
Part AC Generators
ENGINE-GENERATOR Drive System
Rotor Assembly
AC Generator
Brush Holder and Brushes
Stator Assembly
Other AC Generator Components
Excitation Circuit Breaker
Main Line Circuit Breaker
Voltage Regulator
Field Boost Circuit
Rotor Residual Magnetism
Field Boost
Operation
Troubleshooting Flowcharts
Troubleshooting Flowcharts Part
Section
Section
Procedure
Safety
Test 1- Check Main Circuit Breaker
Discussion
If a high voltage is indicated, go on to Test
Test 2- Check AC Output Voltage
Test 3- Test Excitation Circuit Breaker
Set VOM to AC volts
Test 4- Fixed Excitation Test Rotor AMP Draw Test
Test 6 Check Field Boost
Test 5 Wire Continuity
Test 7 Testing the Stator with a VOM
Set VOM to the Rx1 scale
Test 8 Resistance Check Rotor Circuit
If continuity was measured in steps 5 and 6 proceed to step
Remove wire 4 from the voltage regulator
Test 9 Check Brushes Slip Rings
Test 12 Check and Adjust Engine Governor
Test 10 Test Rotor Assembly
Test 11 Check AC Output Frequency
Start the engine, let it stabilize and warm up at no-load
Loosen the governor clamp bolt Figure
Procedure 7KW Units
Test 15 Check for Overload Condition
Test 13 Check and Adjust Voltage Regulator
Test 14 Check Voltage Frequency Under Load
Test 16 Check Engine Condition
Part Type Prepackaged Transfer Switches
Enclosure
Transfer Mechanism
Limit Switches XA1 and XB1
Utility Closing Coil C1
Standby Closing Coil C2
Neutral LUG
Transfer Relay
Manual Transfer Handle
Terminal Block
Utility 1
Fuse Holder
Terminals 23
Fuses F1, F2
Operational Analysis
Wiring Diagram and Schematic
Utility Source Voltage Available
Utility Source Power Available
Utility Source Voltage Failure
Generator Power Available, Waiting to Transfer
Transfer Action to Standby Position
Transfer to Standby
Generator Powering Load
Utility Restored, Generator Still Providing Output to Load
Utility Restored
Utility Restored, Transfer Relay De-energized
Utility RESTORED, Transfer Switch DE-ENERGIZED
Utility RESTORED, Retransfer Back to Utility
Transfer Switch in Utility
Transfer Switch in Utility
Introduction to Troubleshooting
Troubleshooting Flow Charts Part
If the generator has been shut down, proceed as follows
Test 21- Check Voltage AT Terminal Lugs E1, E2
Test 22 Check Voltage AT Standby Closing Coil C2
Test 23 Test Transfer Relay TR
Test 24- Check Manual Transfer Switch Operation
Now, connect the VOM test leads across Relay Terminals 1
Continuity Results
Test 25- Test Limit Switch XB1
Test 27- Check Voltage AT Terminal Lugs N1, N2
WIRING/CONNECTIONS
PROCEDURE/RESULTS
Test 29- Check Voltage AT Utility Closing Coil C1
Utility 2 Terminals
Test 30 Check Fuses F1 and F2
Test 31 Test Limit Switch XA1
Test 34 Check N1 and N2 Wiring
Test 33 Continuity Test of Wiring C2
Set the AUTO-OFF-MANUAL switch to the OFF position
See Test 32, Step
Test 35 Check Transformer TX
Transformer TX
Part DC Control
Transformer TX
Terminal Strip / Interconnection
Circuit Board
Utility 1 and Utility
Description and Components
AMP Fuse
AUTO-OFF-MANUAL Switch
Control Panel Component Identification
Circuit Condition Utility Source Voltage Available
Operational Analysis
Circuit Condition Initial Dropout of Utility Source Voltage
Initial Dropout Utility Source Voltage
Section
Utility Voltage Dropout Engine Cranking
Section
Circuit Condition Engine Startup and Running
Engine Startup and Running
Section
Initial Transfer to Standby Source
Section
Circuit Condition Utility Voltage Restored
Utility Voltage Restored / RE Transfer to Utility
Section
Circuit Condition Retransfer to Utility and Engine Shutdown
Engine Shutdown
Operational Analysis
Troubleshooting Flow Charts Part
Troubleshooting Flow Charts
Section
Section
Section
Section
Section
Test 42 TRY a Manual Start
Test 41 Check Position of AUTO-OFF Manual Switch
Test 43- Test AUTO-OFF-MANUAL Switch
Set a VOM to measure DC voltage
Replace AUTO-OFF-MANUAL switch, if defective
Inspect Battery Cables
Test 46- Check Battery
Test Battery State of Charge
Test 45- Check 15 AMP Fuse
Test Battery Condition
Test 47 Check Wire 56 Voltage
If battery voltage is not indicated in , go to Test
Test 48- Test Starter Contactor Relay V-TWIN only
Starter Contactor Relay
Test 49- Test Starter Contactor
Shorted, open or grounded armature
Test 50- Test Starter Motor
Conditions Affecting Starter Motor Performance
Checking the Pinion
Tools for Starter Performance Test
Tachometer
Measuring Current
Test Bracket
Remove Starter Motor
Testing Starter Motor
Test 51 Check Fuel Supply Pressure
Testing Starter Motor Performance
Disconnect Wire 14 at the Fuel Solenoid FS
Test 53 Check Circuit Board Wire Output
Set the AUTO-OFF-MANUAL switch to OFF
Test 52 Test Fuel Solenoid
Test 55 Check for Ignition Spark
Test 54 Check Fuel Solenoid
If sparking occurs but engine still wont start, go to Test
Test 56 Check Spark Plugs
Test 57- Check Engine Compression
If ignition spark still has not occurred, proceed to Test
Test 58 Check Shutdown Wire
Test 59 Check and Adjust Ignition Magnetos
Setting Ignition Magneto Armature Air Gap
Check engine crankcase oil level
Test 60- Check OIL Pressure Switch Wire
With oil level correct, try starting the engine
Do the following
Switch terminals
Test 61- Check High OIL Temperature Switch
Replace switch if it fails the test
Remove the High Oil Temperature Switch
Test 63 Check Fuel Regulator
Test 62 Check and Adjust Valves
Procedure Intake and Exhaust
Test 64 Check Battery Charge Output
Test 65 Check Transformer TX Voltage Output
Test 66 Check AC Voltage AT Battery Charger
Set a VOM to measure AC voltage
If voltage was not measured in , go to Test
BCR
Test 68 Check Battery Charge Winding Harness
Set VOM to measure frequency 63 HZ should be measured
Test 69 Check Battery Charger Wiring
Test 70 Check Engine RUN Winding
AT the Circuit Board
Test 73 Test SET Exercise Switch
Test 71 Check N1 and N2 Voltage
Test 76 Check Cranking and Running Circuits
Test 74 Check Remote Start Wiring If Equipped
Test 75 Check Battery Voltage Circuit
Continuity
Test 77 Test Exercise Function
Part Operational Tests
Electrical Checks
Manual Transfer Switch Operation
Type Transfer Switches
Generator Tests Under Load
Checking Automatic Operation
Setting the Exercise Timer
Verify that the AUTO-OFF-MANUAL switch is set to Auto
Part Disassembly
STATOR/ROTOR/ENGINE Removal
Major Disassembly
Remove door
Major Disassembly
Reverse the previous steps to re-assemble
Front Engine Access
Follow Stator/Rotor/Engine removal procedures, Steps
Part Electrical Data
Model
Part SCHEMATIC, 7 KW Home Standby
Model 4456-0
Part SCHEMATIC, 12 & 15 KW Home Standby
Drawing #0D9013-C 1
Part Wiring DIAGRAM, 7 KW Home Standby
Drawing #0D9014-B 1
Drawing #0D9014-B 2
Model 4456-1
Part Wiring DIAGRAM, 12 & 15 KW Home Standby
Drawing #0D8501-B 1
Drawing #0D8501-B 2
Part
Electrical Data
Part
Page
Page
Xxxxxxxxxxxxxxxxxxxxxxxxxxx
Xxxxxxxxxxxxxxxxxxxxxxxxxxx Part
Procedure
Section