Installation Procedure
2.Mounting on high ceiling
(1)Ornament panel can be mounted on ceiling as high as 3 m.
(2) Please install pad as accessary.
1Cut open the pad along cutting ling. Use part a only and discard part b . (Refer to Fig. 4)
2 Install part a of the pad on the place shown in Fig. 5. Refer to Fig. 6.
Cutting line |
|
|
a | 50 | b |
100 |
Place it on the frame. | Leave no space. |
|
Part a of the pad
Fig. 4
Fig. 6
Part a of the pad
Swing flap motor
(3)Wiring on ornament panel Connecting of wiring of the swing
flap motor on ornament panel. (2 places) (Refer to Fit . 10)
If connecting is not made, error code (A7) appears on remote controller. So, make proper connecting.
3. Install ornament panel on indoor unit.
Side of ornament panel
Fig. 5
Side of indoor unit | Fig. 10 |
| Wiring diagram |
For indoor unit installation, please refer to Installation Manual.
(1)As shown in Fig.7,match the position of swing flap motor with that of the indoor unit piping hole , so that ormament panel can be placed on to indoor unit.
(2)Installation of ornament panel
1Place the holding ring on swing flao motor side teporarily on hooks of the indoor unit. (2 pcs)
2Put the other two holding rings on the hooks at both side of the indoor unit. (Care should be taken not to push wiring of swing flap motor into seals).
3Screw in all 4 screws under holding ring for about 15mm. (Pancl will rise).
4Adjust the ornament panel as per Fig. 7 to cover opening on the ceiling.
5Tighten screws to redrce the thickness of seals between ornament and indoor unit to
Caution
Hook
| Holding ring | 1 |
2 | Piping hole position |
|
2
Swing flap motor
3
4
Fig. 7
Indoor unit | Seal |
| |
Ceiling material |
|
5 _ 8mm
Ornament panel
If screws are not tighten tight, problems in Fig, 8 might occur. Tighten screws properly.
Gas leakage.
Gas leakage from roof.
Contamination | Mist exists and drop down. |
Fig. 8
If there are still space after tightening of screws, please readjust the height of indoor unit.
(Refer to Fig. 9)
Leave no space. | Fig. 9 |
|
If indoor unit is at horizontal level and water drainage is smooth, then, indoor unit height can be adjusted throrgh holes at corners of ornament panel.
27