Cautions

Do not damage any parts of the air conditioner that carry refrigerant by piercing or perforating the air conditioner's tubes with sharp or pointed items, crushing or twisting any tubes, or scraping the coatings off the surfaces. If the refrigerant spurts out and gets into eyes, it may result in serious eye injuries.

Do not obstruct or cover the ventilation grille of the air conditioner. Do not put fingers or any other things into the inlet/outlet and swing louver.

Do not allow children to play with the air conditioner. In no case should children be allowed to sit on the outdoor unit.

Specifications

The refrigerating circuit is leak-proof.

The machine is adaptive in following situation

1. Applicable ambient temperature range: For EAA series :

 

 

 

 

Rated

Maximum

Minimum

 

 

Indoor

DB C

27

32

18

 

Cooling

WB C

19

23

14

 

outdoor

DB C

35

43

10

 

 

 

 

WB C

24

26

6

 

 

 

 

Heating

Indoor

DB C

20

27

15

 

 

WB C

14.5

--

--

 

 

outdoor

DB C

7

24

-7

 

 

WB C

6

18

--

 

 

 

 

For ERA series:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rated

Maximum

Minimum

 

 

Indoor

DB C

27

32

18

 

Cooling

WB C

19

23

14

 

outdoor

DB C

35

43

-5

 

 

 

 

WB C

24

26

--

 

 

 

 

Heating

Indoor

DB C

20

27

15

 

 

WB C

14.5

--

--

 

 

 

 

 

outdoor

DB C

7

24

-7

 

 

WB C

6

18

--

 

 

 

2.If the supply cord is damaged, it must be replaced by the manufacturer or its service agentor a similar qualified person.

3.If the fuse on PC board is broken please change it with the type of T 3.15A /250VAC.

4.The wiring method should be in line with the local wiring standard.

5.The power and connecting cable are self- provided, For series 142, 182 (*EAA), The requirement of the power cable:

H05RN-F 3G 2.5mm2 .

The requirement of connecting cable: H05RN-F 3G 2.0mm2 +H05RN-F 1x0.75mm2. For other series, refer to outdoor operation manual to select teh power cable and connecting cable.

6.The breaker of the air conditioner should be all-pole switch; and the distance between its two contacts should be no less 3mm. Such means for disconnection must be incorporation in the fixed wiring.

7.The waste battery shall be disposed properly.

8.The indoor unit installation height is at least 2.5m.

9.The air breaker and the power switch should installed the conveniently reachable pleace for user.