Location Requirements
IMPORTANT: Observe all governing codes and ordinances.
Check the location where the air conditioner will be installed. Make sure you have everything necessary for correct installation.
The location should provide:
■Heat/Cool
■Cool Only
NOTE: Do not use an extension cord.
■Free movement of air in room to be cooled.
■A large enough opening for the air conditioner. Installation parts are supplied for
■Adequate wall support for weight of air conditioner. Air conditioner weighs 88 lbs to 100 lbs (40 kg to 45 kg).
NOTES:
■Cabinet louvers must not be obstructed. Air must be able to pass freely through the cabinet louvers.
■Your model may differ from the one shown.
A
Window Installation
Window opening measurements:
■22³⁄₄" min. to 32⁵⁄₈" max. (57.8 cm to 82.9 cm) opening width.
■15" (38.1 cm) minimum opening height.
A |
B |
A. 22³⁄₄" min. (57.8 cm) |
B. 15" min. (38.1 cm)
A. Cabinet louvers
Electrical Requirements
WARNING
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death, fire, or electrical shock.
The electrical ratings for your air conditioner are listed on the model and serial number label. The model and serial number label is located on the
Specific electrical requirements are listed in the chart below. Follow the requirements for the type of plug on the power supply cord.
Power supply cord Wiring requirements
■
■
■
■Use on single outlet circuit only.
4