Location Requirements

Location Requirements

IMPORTANT: Observe all governing codes and ordinances.

Check the location where the air conditioner will be installed. Make sure you have everything necessary for correct installation.

The location should provide:

Heat/Cool Models—Grounded electrical outlet within 4 ft (122 cm) of where the power cord exits the air conditioner.

Cool Only Models—Grounded electrical outlet within 6 ft (182.9 cm) of where the power cord exits the air conditioner.

NOTE: Do not use an extension cord.

Free movement of air in room to be cooled.

A large enough opening for the air conditioner. Installation parts are supplied for double-hung windows.

Adequate wall support for weight of air conditioner. Air conditioner weighs 88 lbs to 100 lbs (40 kg to 45 kg).

NOTES:

Cabinet louvers must not be obstructed. Air must be able to pass freely through the cabinet louvers.

Your model may differ from the one shown.

A

Window Installation

Window opening measurements:

22³⁄₄" min. to 32⁵⁄₈" max. (57.8 cm to 82.9 cm) opening width.

15" (38.1 cm) minimum opening height.

A

B

A. 22³⁄₄" min. (57.8 cm)

B. 15" min. (38.1 cm)

A. Cabinet louvers

Electrical Requirements

Window InstallationWARNING

Electrical Shock Hazard

Plug into a grounded 3 prong outlet.

Do not remove ground prong.

Do not use an adapter.

Do not use an extension cord.

Failure to follow these instructions can result in death, fire, or electrical shock.

The electrical ratings for your air conditioner are listed on the model and serial number label. The model and serial number label is located on the right-hand side of the air conditioner cabinet.

Specific electrical requirements are listed in the chart below. Follow the requirements for the type of plug on the power supply cord.

Power supply cord Wiring requirements

115-volt (103.5 min. - 126.5 max.)

0-12 amps

15-amp time-delay fuse or circuit breaker

Use on single outlet circuit only.

4

Page 4
Image 4
Haier CWH08A Location Requirements, Electrical Requirements, Window Installation, Power supply cord Wiring requirements