It is the customer’s responsibility to contact a qualified electrician to ensure that the electrical installation is adequate and conforms with all national and local codes and ordinances.

You must have:

120-volt, 60Hz, AC-only, 15- or 20-amp.,fused electrical supply.

COPPER WIRE ONLY.

We recommend:

A time-delay fuse or circuit breaker.

A separate circuit.

If direct-wiring dishwasher

• Use flexible, armored or non-metallic sheathed copper wire with grounding wire that meets the wiring requirements for your home and local codes

and ordinances.

Use strain relief method provided with house wiring

junction box or install a UL-listed/CSA-certified clamp connector to the house wiring junction box. If using conduit, use a UL-listed/CSA-certified conduit connector.

If connecting dishwasher with a power supply cord

• Use a UL-listed, 16-gauge, three-conductor power supply cord that meets

all local codes and ordinances. Maximum length of the power supply cord is

6 feet (1.8m).

A clamp connector to fit a 7/8” (2.2cm) diameter hole is required to secure power supply cord to dishwasher terminal box.

• Power supply cord must plug into a mating three-prong, grounded outlet located in the cabinet next to the dishwasher opening.

Outlet must meet all local codes and ordinances.