Chapter 11: Connecting the Switch
a.Remove the jumpers on the power supply terminal block.
b.Secure the ring lug of the positive (+) DC power source cable from the first DC power source to the A+ terminal on the first DC power supply.
c.Secure the ring lug of the negative
d.Secure the ring lug of the positive (+) DC power source cable from the second DC power source to the A+ terminal on the second DC power supply.
e.Secure the ring lug of the negative
f.Tighten the screws on the power supply terminals on both the power supplies until snug using the Phillips (+) screwdriver, number 2. Do not
Figure 58: Securing Ring Lugs to the Terminals on the DC Power Supply in an EX3200 or EX4200 Switch
6.Replace the terminal block cover and secure it using the screw. Use the Phillips (+) screwdriver, number 2 to tighten the screw.
7.Close the input circuit breaker.
8.Verify that the LEDs on the power supply are lit green and are on steadily.