Complete Hardware Guide for EX3200 and EX4200 Ethernet Switches
NOTE: The DC power supply in EX3200 and EX4200 switches does not support Power over Ethernet (PoE); you can use either an external power injector or an AC power supply to supply power to PoE devices that you connect to the switch.
NOTE: For DC power supplies, we recommend that you provide at least 7.5 A @ 48 VDC and use a facility circuit breaker rated for 10 A minimum. Doing so enables you to operate the switch in any configuration without upgrading the power infrastructure, and allows the switch to function at full capacity using multiple power supplies.
Related Topics ■ AC Power Cord Specifications for EX3200 and EX4200 Switches on page 98
■Power Supply in EX3200 and EX4200 Switches on page 26
■General Safety Guidelines and Warnings for EX Series Switches on page 207
■General Electrical Safety Guidelines and Warnings for EX Series Switches on page 235
AC Power Cord Specifications for EX3200 and EX4200 Switches
Detachable AC power cords are supplied with the switch. The coupler is type C13 as described by International Electrotechnical Commission (IEC) standard 60320. The plug at the male end of the power cord fits into the power source outlet that is standard for your geographical location.
CAUTION: The AC power cord for the switches is intended for use with that switch only and not for any other use.
NOTE: In North America, AC power cords must not exceed 4.5 meters (approximately
14.75feet) in length, to comply with National Electrical Code (NEC) Sections
Table 31 on page 98 lists AC power cord specifications provided for each country or region.
Table 31: AC Power Cord Specifications
Country/Region | Electrical Specifications | Plug Standards |
Australia | 250 VAC, 10 A, 50 Hz | AS/NZ |