Haier HPU-42CF03 operation manual When problems occur, Errors display

Models: HPU-42CF03

1 29
Download 29 pages 42.29 Kb
Page 20
Image 20
1. Errors display

Manual background When problems occur

1. Errors display

Inspection display

Contents of breakdown

The "Power" light flashes once

Room temp. sensor abnormal

The "Power" light flashes twice

Indoor coil temp. sensor abnormal

The "Power" light flashes sixteen times

Outdoor low pressure or compressor discharge

 

temperature abnormal

The "Power" light flashes four times

Outdoor defrosting sensor abnormal (Heat pump unit)

 

 

2. Power supply

Manual background The parameter of power cord is over 2.5mm2x5.

Manual background The parameter of connect cord is 0.75mm2x4 .

Manual background Air conditioner must use an exclusive line (over 30A)

Manual background When installation air conditioner in a wet place, try to use a circuit breaker against current leakage.

Manual background For installation in other places, use circuit breaker as far as possible.

Manual background The breaker of the air conditioner should be all-pole switch ; and the distance between its two contacts should be no less than 3 mm.

Manual background Such means for disconnection must be incorporation in the fixed wiring