When problems occur
1. Errors display
Inspection display | Contents of breakdown |
The "Power" light flashes once | Room temp. sensor abnormal |
The "Power" light flashes twice | Indoor coil temp. sensor abnormal |
The "Power" light flashes sixteen times | Outdoor low pressure or compressor discharge |
| temperature abnormal |
The "Power" light flashes four times | Outdoor defrosting sensor abnormal (Heat pump unit) |
|
|
2. Power supply
The parameter of power cord is over 2.5mm2x5.
The parameter of connect cord is 0.75mm2x4 .
Air conditioner must use an exclusive line (over 30A)
When installation air conditioner in a wet place, try to use a circuit breaker against current leakage.
For installation in other places, use circuit breaker as far as possible.
The breaker of the air conditioner should be
Such means for disconnection must be incorporation in the fixed wiring