Hampton Direct H25-NG1, H25-LP1 Venting Arrangements, Installation, after fi rst sale

Models: H25-NG1 H25-LP1

1 44
Download 44 pages 38.92 Kb
Page 14
Image 14
VENTING ARRANGEMENTS

INSTALLATION

 

VENTING ARRANGEMENTS

Horizontal Terminations for

Vertical Terminations Systems for

All Venting Systems

Residential Manufactured and Mobile Homes

The shaded areas in the diagram below show all allowable combinations of vertical runs with hori- zontal terminations. Maximum one 90O elbow (two 45o elbows equal one 90o elbow).

Propane and Natural Gas:

Residential, Manufactured and Mobile

Homes Installations

May be installed in Manufactured (Mobile) Homes

after fi rst sale.

The shaded area in the diagram below shows all allowable combinations of straight vertical and offset to vertical runs with vertical terminations. Maximum two 45o elbows.

If the vent is ENCLOSED in a chase (min. size 9" x 9") maintain a 1-1/4" clearance to combustibles.

May be installed in Manufactured (Mobile) Homes after fi rst sale.

Offset to Vertical Terminations

Venting Arrangements - Horizontal Terminations using Dura-Vent venting system

The two diagrams show all allowable com- binations of straight horizontal termination with one 45o elbow off the unit and Dura- Vent Snorkel or FPI Riser Vent. Restrictor position "A".

Dura-Vent Snorkel Termination

Riser Vent Termination

14

Hampton® H25-1 Direct Vent Freestanding Gas Stove

Page 14
Image 14
Hampton Direct H25-NG1 Venting Arrangements, Installation, May be installed in Manufactured Mobile Homes, after fi rst sale