Hampton Direct H25-LP1, H25-NG1 Installation, WARNING Electrical Grounding Instructions

Models: H25-NG1 H25-LP1

1 44
Download 44 pages 38.92 Kb
Page 9
Image 9
WARNING: Electrical Grounding Instructions

INSTALLATION

9)Place the blower close to the base of the unit and feed the long red and black wires through the opening of the base of the unit and connect them to the thermodisc.

12)Before re-attaching the rear access panel, the valve wires and the fan wires need to be connected.

Re-connect the red and grey valve wires.

Connect the fan wires.

10)Feed the short red and black wires through the small hole at the base of the unit.

11)Mount the blower assembly in position under the base of the stove and secure with the 2 supplied bolts (2-1/4" #20 hex head)

13)Slide the Rear Access Panel back into position and secure with 2 screws.

WARNING: Electrical Grounding Instructions

This appliance is equipped with a three pronged (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from this plug.

Hampton® H25-1 Direct Vent Freestanding Gas Stove

9

Page 9
Image 9
Hampton Direct H25-LP1, H25-NG1 installation manual Installation, WARNING Electrical Grounding Instructions