INSTALLATION

RESIDENTIAL AND MANUFACTURED HOMES / MOBILE HOMES

MINIMUM HORIZONTAL TERMINATION INSTALLATIONS

Planning Your venting Installation

See the "Exterior Vent Terminatal Locations" sectionforrequirements.TheH25isapproved for a minimum horizontal termination with the FPI Riser Vent Kit. See the diagram for minimum and maximum pipe lengths.

You will require the following components with your new Hampton® Rear Vent Direct Vent Free- standing Gas Stove. Please review your product to make sure you have everything you need. In the event that you are missing any part, contact your dealer. Decorative brass

or chrome trim kits are available from Simpson Dura-Vent for their wall thimbles, as well as a square wall thimble cover.

When planning your installation, it will be nec-

 

 

 

 

essary to select the proper length of vent pipe

 

 

 

 

for your particular requirements. Determine the

 

 

 

Horizontal

minimum clearance to combustibles from the

 

 

 

 

 

 

Terminal

rear of the unit to the wall. It is also important to

 

 

 

 

 

 

Part# 640-530/P

note the wall thickness. Before cutting the vent

 

 

 

 

 

 

 

hole through the wall ensure that ALL vent and

 

 

 

Vinyl Siding

termination clearances (see the "Exterior Vent

 

 

 

Standoff (Optional)

Terminal locations" section) will be met.

 

 

 

Part #946-205

 

 

 

 

Wall Thimble

*Ifthisisanoutsidecorner,theminimumdistance

 

Decorative

 

(required for

between the vent and the outside corner is 6"

Adapter

Wall Trim

combustible walls)

 

Part # 946-202

(15cm). See "F" on the diagram in the "Exterior

Part #946-219/P

Part #640-545/P

Vent Terminal Locations" section.

(required)

 

 

 

 

Pipe Length (max. 18")

 

 

 

 

 

 

 

 

Part (6-5/8" Dia)

 

 

 

 

(4" Dia.)

 

 

 

Note: Thesearetheminimumpiecesrequired.

 

 

 

Other parts may be required for your

 

 

 

particular installation.

 

 

NOTE: Ensure compliance with the outside vent terminal location before cutting hole as both dimensions must be met.

Minimum components for a Horizontal Installation:

640-944 Horizontal Termination Kit which includes:

1

 

6-5/8" Dia. x 18" Black Pipe

1

 

4" Dia. x 18" Aluminum Vent

1

946-202

Wall Penetration Heat Shield (Wall Thimble) (2 pcs)

1

640-530/P

Riser Vent Terminal

1

640-545/P

Decorative Wall Trim (Black)

1

948-128

Tube Mill-Pac

946-219/P 1

Adapter

Screws

 

Optional Components:

 

946-204

45o Elbow - 6-5/8" Black pipe

 

and 4" Aluminum Vent

946-205

Vinyl Siding Shield for Riser Vent

 

Terminal

 

946-208/P

Vent Guard

 

940

Square Wall Thimble Cover*

981Snorkel Termination (36")*

982Snorkel Termination (14")*

942

Wall Penetration

 

Heat Shield*

* Simpson Dura-Vent components

20

Hampton® H25-1 Direct Vent Freestanding Gas Stove

Page 20
Image 20